User Manual For DATCOM Components

46
Technical Data
Datalogger Card / Box
Memory Capacity 540 KB
Memory duration approx. 1000 days
(1 Fronius IG or Fronius IG Plus, memory cycle 30 minutes)
Supply voltage 12 V DC
Power consumption 0.4 W
- With wireless transceiver box: max. 0.6 W
Box protection class IP 20
Dimensions (l x w x h)
- Datalogger card: 140 x 100 x 26 mm
- Datalogger box: 190 x 115 x 53 mm
Datalogger card interfaces Socket: Description:
- USB: USB „USB“
- RS 232: 9-pin submin „PC“
- RS 232: 9-pin submin „Modem“
Datalogger box interfaces
- USB: USB „USB“
- RS 232: 9-pin submin „PC“
- RS 232: 9-pin submin „Modem“
- RS 485: RJ 45 „IN“
- RS 485: RJ 45 „OUT“
Datalogger & Interface (Box)
Memory Capacity 540 KB
Memory duration approx. 1000 days
(1 Fronius IG or Fronius IG Plus, memory cycle 30 minutes)
Supply voltage 12 V DC
Power consumption 2.8 W
Box protection class IP 20
Dimensions (l x w x h) 210 x 110 x 72 mm
Interfaces Socket: Description:
- USB: USB „USB“
- RS 232: 9-pin submin „PC“
- RS 232: 9-pin submin „Modem“
- RS 232: 9-pin submin „Data“
- RS 485: RJ 45 „IN“
- RS 485: RJ 45 „OUT“
Datalogger
Card / Box
Datalogger &
Interface