User Manual For DATCOM Components
Table Of Contents
6
Installing
Plug-in Cards
Fronius IG
To install plug-in cards, proceed as follows:
- Set the Fronius IG to „Standby“ (see „The Setup Menu“ in the Fronius
IG operating instructions)
2. Disconnect the Fronius IG from both the AC and DC-sides
3. Open connection area - see „Opening Housing“ in the Fronius IG
operating instructions
4. Slide the display to the left, lift up and remove.
5. Loosen the fixing screw (1) from a free slot and remove the slot cover
(1)
(2)
NOTE Plug-in cards may be damaged. Follow general ESD pre-
cautions when handling plug-in cards.
In general, each plug-in card will fit into each slot. However, we recom-
mend the following:
- ENS card (only required in specific countries):
- When using all card slots:
Insert the Com card into the farthest slot on the right
Insert the remaining plug-in cards into the center slots
- When not using all card slots: Insert plug-in cards as required
- ENS card not present:
- Insert the Com card into the farthest slot on the left
- Insert the remaining plug-in cards as required
- Insert plug-in card (2) into the slot
- Secure plug-in card (2) using fixing screw (1)
- Close housing
- Connect AC and DC lines to the Fronius IG