40
The Basic menu
General The Basic menu is used to set the following parameters, which are important for installing
and operating the inverter:
Access the Basic
menu
- DC operating mode
- Fixed voltage
- MPPT1 initial voltage
- USB logbook
- Insulation settings
- TOTAL reset
- Event counter
Press the 'Menu' key
The menu level appears.
Press the unassigned 'Menu / Esc'
key
5 times
"Access Code" is displayed in the "CODE"
menu; the first digit starts flashing.
Enter the code 22742: Use the 'Up'
and 'Down' keys to select a value for
the first digit of the code
Press the 'Enter' key
The second digit starts flashing.
Repeat steps 3 and 4 for the second,
third, fourth and fifth digit of the ac-
cess code until ...
the selected code starts flashing.
Press the 'Enter' key
The Basic menu appears.
Use the 'Up' or 'Down' keys to select
the desired menu item
Press the 'Enter' key to open the de-
sired menu item
Press the 'Esc' key to exit the Basic
menu
1
2
3
4
Access Code
5
6
MPP Tracker 1
USB Eventlog
Input signal
SMS / Relay
Grounding Settings
7
8
9