Card

91
EN-US
S0 inverter
(1a) Counter position at feed-in point
The power of feeding in and energy are measured. The consumption is determined
using these values and the system data.
An S0 counter must be configured at this position in order to count the fed-in ener-
gy.
IMPORTANT! If you are using an S0 counter at the feed-in point, the counter data
will not be displayed on Fronius Solar.web. This option is only provided for dynamic
power reduction.
The consumption values can be detected to a limited extent when feeding into the
grid.
(1b) Counter position in consumption branch
The power consumed and energy are measured directly. The power of feeding in
and energy are determined using these values and the system data.
An S0 counter must be configured at this position in order to count the energy con-
sumed.
(1c) Field for entering the impulses per kWh
A counter for recording self-consumption per S0 can be connected directly to the inverter
(Fronius Galvo and Fronius Symo only).
IMPORTANT! An S0 counter is connected to the switchable multifunctional current inter-
face of the inverter. Connecting an S0 counter to the inverter may require an inverter firm-
ware update.
(1)
(
2
)
(1a) (1b)
(1c)
(1a)
(1b)