Installation Guide
5
30” ELECTRIC FRONT CONTROL FREESTANDING INSTALLATION INSTRUCTIONS
Fig. 13
6. Installing Power Cords 
(United States)
RISK OF FIRE OR ELECTRICAL SHOCK MAY OCCUR IF 
AN INCORRECT SIZE RANGE CORD KIT IS USED, THE 
INSTALLATION INSTRUCTIONS ARE NOT FOLLOWED 
OR STRAIN RELIEF BRACKET IS DISCARDED.
This appliance may be connected by means of a power 
supply cord. Use a power supply cord kit rated at 125/250 
volts minimum, marked for use with ranges. 
Cord must have either three (3) or four (4) conductors. 
Terminals on end of wires must be either closed loop or 
open-end spade lugs with upturned ends. 
Cord must have strain relief properly installed. 
Access the Terminal Block
1.  Remove the access cover and bracket from the back 
of the appliance. Keep all pieces and the screws. 
2.  Pull the cord terminals through the correct hole in the 
bracket included with the appliance.
3.  Connect the terminals to the terminal block 
as instructed for 3-wire, 4-wire, or permanent 
connections. See the next section for specic 
instructions for each connection. 
4.  Place the strain relief through the included bracket and 
tighten against the power cord. 
5.  Replace the bracket and access cover on the 
appliance.
Required for new and
remodeled installations
4-Wire Wall
receptacle (14-50R)
Allowed for
existing installations
3 Wire Wall
receptacle (10-50R)
 Fig. 10
 Fig. 11
 Fig. 9
Fig. 12