Manual

To wire through top:
2.Mark a line distance (A) from the right of the
centerline on the underside of the cabinet. Mark the
point on this line that is 7/8"(2.2 cm) from back wall.
Drill a 11/4" (3.2 cm) diameter hole (B) through the
cabinet at this point.
I I I
I _ll I
B
i
t
I
\
7/8" (2.2 cm)
from wall,
not cabinet frame
i
Centerline
To wire through wall:
1.Mark a line distance (A) from the right of the
centerline on the underside of the wall. Mark the point
on this line that is 7/8" (2.2 cm) from the underside of
the cabinet. Drill a 11/4" (3.2 cm) diameter hole (B)
through the rear wall at this point.
1! (2.2 cm)
A Centerline
VENTING
Choose venting exhaust discharge from the various
options listed - Style 1 - 4 that follows:
Style 1 - Recirculating Hood version
For this installation, go to "Install Range Hood
(recirculating version)" on page 13.
Style 2 - Cut Openings for 31/4" x 10" (8.3 cm x
25.4 cm) Rectangular Vent System
Roof Venting
To make a 4"x 101/2"(10.16 cm x 26.7 cm) rectangular
cutout on the underside of cabinet top and bottom:
1.Mark lines 1/2"(1.3 cm) and 43/4" (12.1 cm) from the
back wall on the centerline of the underside of cabinet.
2.Mark lines 51/4"(13.3 cm) to the right and left of the
centerline on the underside of cabinet.
3.Use saber or keyhole saw to cut a rectangular opening
for vent.
4.Repeat steps 1-3 for the underside of the top of the
cabinet.
Centerline
;'J \
Cabinet cutouts .... I
i
"1/2(1.3 cm)
Wall Venting
To make a 31/2"x 101/2" (8.9 cm x 26.7 cm) rectangle in
the wall:
1.Make 2 lines by measuring %" (0.9 cm) and 3Y8"
(9.8 cm) down from underside of cabinet and mark on
the centerline on the back wall.
2.Mark lines 51/4"(13.3 cm) to the right and left of the
centerline on the wall.
3.Use saber or keyhole saw to cut a rectangular opening
in the wall for the vent.
Centerline
Cabinet !J
lh_ rout i J
5V4" 51/4''
(13.3 cm)(13.3 cm)