Installation Guide
9
To wire through top:
Mark a line distance (A) from the right of the   
  centerline on the underside of the cabinet. Mark the 
  point on this line that is 
7
⁄8” (2.2 cm) from back wall. 
  Drill a 1¼” (3.2 cm) diameter hole (B) through the cab 
  net at this point. 
To wire through wall:
Mark a line distance (A) from the right of the 
  centerline on the underside of the wall. Mark the point 
  on this line that is 
7
⁄8” (2.2 cm) from the underside of  
  the cabinet. Drill a 1¼” (3.2 cm) diameter hole (B) 
  through the rear wall at this point. 
VENTING 
Chooseventingexhaustdischargefromthevarious 
options listed - Style 1 - 4 that follows: 
Style 1 - Recirculating Hood version 
For this installation, go to “Install Range Hood 
(recirculating version)” on page 11.
2.
1.
A
Centerline
7
⁄8” (2.2 cm)
from wall,
not cabinet frame
B
A
A Centerline
7
⁄8” 
(2.2 cm)
B
Style 2 - Cut Openings for 3¼” x 10” (8.3 cm x 
25.4 cm) Rectangular Vent System
Roof Venting
Tomakea4”x10½”(10.16cmx26.7cm)rectangular
cutout on the underside of cabinet top and bottom:
Mark lines ½” (1.3 cm) and 4¾” (12.1 cm) from the   
  back wall on the centerline of the underside of cabinet.
Mark lines 5¼” (13.3 cm) to the right and left of the   
  centerline on the underside of cabinet.
Use saber or keyhole saw to cut a rectangular opening 
  for vent.
Repeat steps 1-3 for the underside of the top of the   
  cabinet.
Wall Venting
Tomakea3½”x10½”(8.9cmx26.7cm)rectanglein
the wall:
Make 2 lines by measuring 
3
⁄8” (0.9 cm) and 3
7
⁄8” 
  (9.8 cm) down from underside of cabinet and mark on 
  the centerline on the back wall.
Mark lines 5¼” (13.3 cm) to the right and left of the 
  centerline on the wall.
Use saber or keyhole saw to cut a rectangular opening 
  in the wall for the vent.
1.
2.
3.
4.
1.
2.
3.
Cabinet cutouts
*From wall, not cabinet frame
*
1
/2 (1.3 cm)
5
1
/4 
(13.3 cm)
5
1
/4 
(13.3 cm)
*4
3
/4 
(12.1 cm)
Cabinet  
front
Centerline
5
1
/4”
(13.3 cm)
3
7
/8” 
(9.8 cm)
3
/8” 
(0.9 cm)
5
1
/4”
(13.3 cm)
Centerline
PREPARE THE LOCATION
hood 
model
Dim 
A
30” & 36” 
models
8³⁄8” 
(21.3 cm)
hood 
model
Dim 
A
30” & 36” 
models
8³⁄8” 
(21.3 cm)