Installation Guide
5
LIST OF MATERIALS
LIST OF MATERIALS 
Parts included in your hood
4-0.45x1.3cmmountingscrews
3¼”x10”(8.3x25.4cm)rectangularmetalvent 
  system. 
NOTE: An optional 7” round duct kit is available. You can 
order this kit as part number 5304487139.
Parts Needed
2 - UL listed wire connectors
1-75Wmax,120Vincandescentlightbulb
Wall or roof cap with damper to match vent system
Vent clamps/duct tape as required 
UL listed or CSA approved ½” strain relief
Tools/Materials required
Drill
1¼” (3.0 cm) drill bit
⅛”(0.3cm)drillbitforpilotholes
Pencil
Wire stripper or utility knife
Tape measure or ruler
Caulking gun and weatherproof  
  caulking compound
Flat-blade screwdriver
Phillips screwdriver
Saber or keyhole saw 
For cabinets with recessed bottoms:
Two2”(5.1cm)widellerstrips.Lengthand 
  thickness determined by recess dimensions.
Fouratheadwoodscrewsormachinescrews
 withwashersandnuts(toattachllerstrips).
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
ELECTRICAL REQUIREMENTS 
Observe all governing codes and ordinances.
Ensure that the electrical installation is adequate and in 
conformance with National Electrical Code, ANSI/NFPA 
70 (latest edition), or CSA Standards C22.1-94, Canadian 
Electrical Code, Part 1 and C22.2 No. 0-M91 (latest edi-
tion) and all local codes and ordinances.
If codes permit and a separate ground wire is used, it is 
recommendedthataqualiedelectriciandeterminethat
the ground path is adequate.
A copy of the above code standards can be obtained 
from:
National Fire Protection Association
One Batterymarch Park
Quincy, MA 02269
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
A 120 volt, 60 Hz., AC only, 15-amp, fused 
  electrical circuit is required.
If the house has aluminum wiring, follow the 
  procedure below:
Connect a section of solid copper wire to the  
  pigtail leads.
Connect the aluminum wiring to the added 
  section of copper wire using special co   
  nectors and/or tools designed and UL listed 
  for joining copper to aluminum.
Follow the electrical connector manufacturer’s recom-
mended procedure. Aluminum/copper connection must 
conform with local codes and industry accepted wiring 
practices.
Wire sizes and connections must conform with 
 theratingoftheapplianceasspeciedonthe 
  model/serial rating plate. 
  The model/serial plate is located on the left side of 
  the range hood.
Wire sizes must conform to the requirements of 
  the National Electrical Code, ANSI/NFPA 70 (la 
  est edition), or CSA Standards C22. 1-94, Canad 
  an Electrical Code, Part 1 and C22.2 No. 0-M91 
  (latest edition) and all local codes and ordinances.
•
•