30" min.
13" 
max.
 25"
Minimum 
clearance (A)
required to 
nearest 
combustible 
wall on 
either side 
of range 
above 36"
height
30"
C
L
36"
stand.
Wall
15"
11
1
/2"
Recommended area for through-the-floor 
connection of pipe stub and shutoff valve 
8"
Recommended area for 120V outlet on rear of 
wall and area for through-the-wall connection 
of pipe stub and shutoff valve 
23"
18"
min.
24"
10 
1
/2"
2"
18"
min.
Front
29
7
/8"
48
1
/2"
max.
46
5
/8"
Gas inlet location
(right bottom rear*)
Power cord location
(left bottom rear*)
 *when viewed from front
Side
25
3
/
4
"
29
1
/4"
30" Gas Freestanding Ranges 
Frigidaire Baseline
30" 
min.*
Clearance (A)
  Based on Largest  Minimum
  Burner Output Rating  Clearance
  on Cooking Surface  Required
  9,500 BTU or less   2"
 10,000
-
16,999 BTU   3"
 17,000 BTU or greater   5"
* Min. distance from cooking surface 
to underside of overhead cabinetry
36"
(Adjustable 
to 
±
1
/8")
Note: Overall 
product dimensions 
are model specific 
and may vary slightly 
from illustration. Refer 
to model’s product 
specifications for 
actual dimensions. 
USA
 • 
10200 David Taylor Drive
 • 
Charlotte, NC 28262
 • 
1-800-FRIGIDAIRE
 • 
frigidaire.com 
CANADA
 • 
5855 Terry Fox Way
 • 
Mississauga, ON L5V 3E4
 • 
1-800-265-8352
 • 
frigidaire.ca
FFGF3051T 03/17  © 2017 Electrolux Home Products, Inc.
Freestanding Range Specifications
•
 Product Shipping Weight (approx.) – 170 Lbs.
•
 Voltage Rating – 120V / 60 Hz / 5 Amps
•
 Amps @ 120 Volts = 5 Amps
•
 Always consult local and national electric and gas codes.
•
 Make sure wall coverings around range can withstand heat generated 
by range.
•
 Linoleum or any other synthetic floor covering located beneath range, 
must be capable of withstanding minimum heat of 90° F above room 
temperature without shrinking, warping or discoloring. Insulating pad 
or 1/4"-thick plywood required between range and a carpeted floor.
•
 Do not obstruct flow of combustion air at oven vent nor around base 
or beneath lower front panel of range. Range requires fresh air for 
proper burner combustion.
•
 Do not install range beneath any downward-blowing, overhead vent 
hood or air curtain.
•
 Range ships with 3/4" factory regulator. 
•
 Range is LP Gas convertible. (Optional LP Gas Conversion  
Kit available.) 
•
 Floor beneath range MUST be solid and level.
•
 Overhead cabinetry should not exceed a 13" maximum depth.
•
 Absolute minimum horizontal distance between overhead cabinets 
installed to either side of appliance must be no less than maximum  
width of appliance.
•
 Range can be installed flush to wall with 0" minimum rear clearance.
•
 Minimum clearance required (from edge of rangetop to nearest 
combustible wall on either side of range above 36" height) is based 
on largest burner output rating on cooking surface.
•
 To reduce risk of fire when using overhead cabinetry, install  
range hood that projects horizontally a recommended minimum  
of 5" beyond bottom of cabinets.
•
 Follow all dimension requirements provided to prevent property 
damage, potential fire hazard, and incorrect countertop and  
cabinet cuts.
Note: For planning purposes only. Refer to Product Installation Guide  
on the web at frigidaire.com for detailed instructions.
Optional Accessories
•
 LP Gas Conversion Kit – (PN # GRLP4).
Freestanding Ranges
FFGF3051T S / W/ B 30" Gas