Specification

Specifications
subject to change.
USA
10200 David Taylor Drive
Charlotte, NC 28262
1-800-FRIGIDAIRE
frigidaire.com
CANADA
5855 Terry Fox Way
Mississauga, ON L5V 3E4
1-800-265-8352
frigidaire.ca
FGGF3685T 06/17 © 2017 Electrolux Home Products, Inc.
Freestanding Range
FGGF3685TS 36" Gas
Freestanding Range Specifications
Product Shipping Weight (approx.) – 395 Lbs.
Voltage Rating – 120V / 60 Hz / 7Amps
Always consult local and national electric and gas codes.
Make sure wall coverings around range can withstand heat generated
by range.
Linoleum or any other synthetic floor covering located beneath range,
must be capable of withstanding minimum heat of 90° F above room
temperature without shrinking, warping or discoloring. Insulating pad
or 1/4"-thick plywood required between range and a carpeted floor.
Do not obstruct flow of combustion air at oven vent nor around base
or beneath lower front panel of range. Range requires fresh air for
proper burner combustion.
Do not install range beneath any downward-blowing, overhead vent
hood or air curtain.
Range ships with 3/4" factory regulator.
Range is LP Gas convertible. (Optional LP Gas conversion
kit available.)
Floor beneath range MUST be solid and level.
Overhead cabinetry should not exceed a 13" maximum depth.
Absolute minimum horizontal distance between overhead cabinets
installed to either side of appliance must be no less than maximum
width of appliance.
Range can be installed flush to wall with 0" minimum rear clearance.
5" minimum clearance required from edge of rangetop to nearest
combustible wall on either side of range above 36" height.
To reduce risk of fire when using overhead cabinetry, install
range hood that projects horizontally a recommended minimum
of 5" beyond bottom of cabinets.
Follow all dimension requirements provided to prevent property
damage, potential fire hazard, and incorrect countertop and
cabinet cuts.
Note: For planning purposes only. Refer to Product Installation Guide
on the web at frigidaire.com for detailed instructions.
Optional Accessories
LP Gas Conversion Kit – (Included).
12"
12"
36" Gas Freestanding Ranges
Frig Gallery
*Miniumum distance
required between
cooking surface and
cabinet bottom
25"
13"
max.
C
L
36"
min.*
Wall
36"
min.
36
1
/4"
min.
35
3
/4"
min.
36"
stand.
Front
36"
max.
36"
49"
max.
Side
47
3
/4"
28
1
/2"
30
3
/4"
Power cord location
(middle bottom rear*)
*when viewed from front
8"
8"
Shaded area is suggested location
for electrical wall outlet which may also be
located on wall in lower left corner of adjacent
right cabinet or on wall in lower right corner
of adjacent left cabinet. (All dimensions
for outlet locations are maximum.)
Minimum
5" clearance
required
from cooking
surface to
adjacent side
walls or other
vertical surfaces
or structures
such as cabinets
18"
min.
18"
min.
Hatched area on right cabinet base floor is
suggested gas supply/shut-off valve location.
Can also be located in left cabinet base floor
on opposite side of cutout opening (Supply
piping can enter through cabinet side wall.)
5"
max.
8"
7"
max.
24"
min.
24
1
/
2
"
max.