Submittal

Specifications
EnErgy Star
®
qualied
As an
EnErgy Star
®
partner, Friedrich Air Conditioning Co. has determined that the selected
EnErgy Star
®
models meet the EnErgy Star
®
guidelines for energy efciency.
WALLMASTER HEAT PUMP
HEATING PERFORMANCE: Chan ge -ove r from heat p ump ope ration to resi stance
operation on models indicated is automatic at a preset outside ambient temperature
of approximately 35°F.
Calc ulate the heat loss of the space to be heated. As l o ng as t h e heat loss does not
exceed the resistance heating capacity rating of the unit, the heating performance
will be satisfactory.
Note: all models will produce condensate. If condensate disposal is desired, an
optional drain kit is available.
DEFROST C O N T ROL: Ini tiated at 30°F (outdoor coil temperature) and ter minated
at 43°F (outdoor coil temperature). During defrost, the compressor stops and the
electric heat star ts, then operates with the fan to maintain indoor comfort. Below
43°F, the unit remains in electric heat mode.
During electric heat mode, the unit will achieve the following ratings: 11000/9100
BTU/h, 16.0/14.7 amps, and 3550/2950 watts.
DEFROST DRAIN: Drain automatically opens at approximately 50°F to prevent
condensate from freezing inside drain pan.
WallMaster Heat Pump heating information indicates heat pump heating performance. WallMaster Electric Heat heating information indicates electric heat strip
performance. For WallMaster Heat Pump electric heating performance refer to corresponding WallMaster Electric Heat model.
Plug Face/ Circuit Rating
WallMaster
Model Number
Circuit Rating
Breaker
or T-D Fuse
Plug Face
(NEMA#)
Power Cord
Length (ft.)
Wall
Outlet
Appearance
WS08C10,WS10C10,
WS12C10
125V-15A 5-15P 6
WS10C30,WS13C30,
WS16C30
250V-15A 6-15P 4
WE10C33,WE13C33,
WE16C33,WY09C33,WY12C33
250V-20A 6-20P 4
Power cords are located on front left of WallMaster models.
Model Height Width Depth
Depth
with
Front
Minimum
Extension
Into Room
Minimum
Ex tension
Outside
Thru-the-wall
Finished Hole
Height Width Max. Depth
WallMaster
WSD Sleeve 16 3/4" 27" 16 3/4" 23" 7 1/2" 9/16" 17 1/4" 27 1/4" 15 5/16"
Chassis 15 3/4" 26 1/2" 21" 22”
Sleeve/Chassis Dimensions
Chassis requires WSD sleeve (sold and shipped separately)
*Installation in Fedders B sleeve requires a bafe kit. See BAK accessory under accessories.
Thru-the-wall_WallMaster_Submittal_2013
Model
Carton Dimensions
INCHES
Height W i d t h Depth
WallMaster
®
WSD Sleeve 18" 27 1/4" 18"
Chassis 18 1/2" 30 1/2" 29"
Uni-Fit
®
USC Sleeve 17 7/8" 28" 19 1/4"
USChassis 17 1/4" 27 3/4" 221/4”
UEChassis 17 1/4" 273/4” 221/4”
LISTED
ROOM AIR CONDITIONERS
183H
Model Cooling Btu Heating Btu
Volts
Rated
Cooling
Amps
Cooling
Watts
Heating
Amps
Heating
Watts
Energy
Efciency
Ratio
EER
Estimated
Yearly
Operating
Cost
Moisture
Removal
Pints/HR CFM Sleeve
Net
Weight
Lbs.
Ship
Weight
Lbs
WALLMASTER
®
Cool only
WS08C10 7800 NA 115 7.1 788 NA NA 9.9
1.2 250 WSD 93 97
WS10C10 9700 NA 115 10.0 1032 NA NA 9.4 $82 2.4 260 WSD 103 107
WS12C10C 11500 NA 115 11.5 1223 NA NA 9.4 $98 3.1 320 WSD 112 116
WS10C30 9500/9200 NA 230/208 4.5/4.7 989/958 NA NA 9.6/9.6 $79 1.5 300 WSD 101 105
WS12C30 11500/11200 NA 230/208 5.5/6.0 1223/1191 NA NA 9.4/9.4 $98 3.0 320 WSD 109 113
WS16C30 15600/15000 NA 230/208 8.3/8.9 1835/1765 NA NA 8.5/8.5 $144 4.2 290 WSD 119 123
HeatPump
WY09C33 9300/9000 7300/7300 230/208 4.4/4.7 989/957 3.8/4.0 839/793 9.4/9.4 $79 2.1 250 WSD 103 107
WY12C33 12000/11800 9350/9200 230/208 6.1/6.4 1395/1372 4.8/5.1 1062/1010 8.6/8.6 $111 2.6 275 WSD 111 115
CoolwithElectricHeat
WE10C33 9500/9200 11000/9100 230/208 4.5/4.7 989/957 16.0/14.7 3550/2950 9.6/9.6 $79 1.5 300 WSD 121 125
WE12C33 11500/11200 11000/9100 230/208 5.5/6.0 1123/1191 16.0/14.7 3550/2950 9.4/9.4 $98 3.0 320 WSD 107 111
WE16C33 15600/15000 11000/9100 230/208 8.3/8.9 1835/1765 16.0/14.7 3550/2950 8.5/8.5 $140 4.2 290 WSD 116 120