Submittal (2021)
Thru-the-wall_WallMaster_Submittal_2020
LISTED
ROOM AIR CONDITIONERS
183H
SPECIFICATIONS
ENERGY STAR
®
 models
HEATING PERFORMANCE:  Change-over from heat pump operation 
to resistance operation on models indicated is automatic at a preset 
outside ambient temperature of approximately 35°F.
Calculate the heat loss of the space to be heated. As long as the heat loss 
does not exceed the resistance heating capacity rating of the unit, the 
heating performance will be satisfactory.
Note: all models will produce condensate. If condensate disposal is 
desired, an optional drain kit is available.
DEFROST CONTROL: Initiated at 30°F (outdoor coil temperature) and 
terminated at 43°F (outdoor coil temperature). During defrost, the 
compressor stops and the electric heat starts, then operates with 
the fan to maintain indoor comfort. Below 43°F, the unit remains in 
electric heat mode.
DEFROST DRAIN: Drain automatically opens at approximately 50°F to 
prevent condensate from freezing inside drain pan.
Heat Pump heating information (shown in red) indicates heat pump heating performance. Electric Heat heating information (shown in red) 
indicates electric heat strip performance. For Heat Pump electric heating performance refer to corresponding Electric Heat model.
Model UPC
Cooling 
Btu
Heating 
Btu
Volts 
Rated
Cooling 
Amps
Cooling 
Watts
Heating 
Watts
Heating 
Amps EER CEER
Estimated 
Yearly 
Energy 
Cost COP
Moisture 
Removal 
Pints 
per Hr. CFM
Wt Lbs
Net/Ship
Cooling Only
WCT08A10A
724587436655
8000 — 115
7.0
748 — — 10.7 10.6 $73 — 1.8 250 93/97
WCT10A10A
724587436662
10000
— 115 9.3 935 — — 10.7 10.6 $92 — 2.4 250 103/107
WCT12A10A
724587436952
12000 — 115
11.1 1250
— —
9.6 9.5
$122 —
3.8 295
101/105
WCT10A30A
724587436945
10000 — 230
4.4 935
— —
10.7 10.6
$92 —
2.7 275
112/116
WCT12A30A
724587436969
12000 — 230 5.4
1250
— —
9.6 9.5
$123 —
3.8 300
109/113
WCT16A30A
724587436976
15400 — 230
7.5 1638
— — 9.4
9.3
$161 — 4.8 290 119/123
Cooling with Heat Pump
WHT12A33A
724587436983 11100 8900
230 5.5
1181 1087 5.0
9.4
9.3
$102
2.4 3.1
275
111/115
Cooling with Electric Heat
WET10A33A
724587436990
10000 11000 230 4.4
935
3550 16.0
10.7 10.6
$92 —
2.7
260 104/108
WET12A33A
724587437003
12000
11000 230
5.4 1250
3550 16.0
9.6 9.5
$123 —
3.8
290 107/111
WET16A33A
724587437010
15400 11000 230 7.5 1638
3550 16.0
9.4 9.3 $161
—
4.8 290 119/123
Power cords are located on front left of WallMaster models.
Due to continuing research in new energy-saving technology, specifications are subject to change without notice.
As an ENERGY STAR
®
 partner, Friedrich Air Conditioning Co. has determined that the selected ENERGY STAR
®
 models meet the  
ENERGY STAR
®
 guidelines for energy efficiency.
EER is the unit’s Energy Efciency Ratio; CEER is the unit’s Combined Energy Efciency Ratio.
Your energy costs will depend on your utility rates and use. The estimated energy cost is based on a electricity cost of $.12 per kWh.
For more information, visit www.ftc.gov/energy.
Model
Circuit 
Rating
Breaker
or T-D Fuse
Plug 
Face
(NEMA#)
Power 
Cord 
Length 
(ft.)
Wall
Outlet
Appearance
WCT08A10A, WCT10A10A and 
WCT10A30A
125V - 15A 5 - 15P 6
WCT12A10A., WCT12A30A and
WCT16A30A.
250V - 15A 6 - 15P 6
WHT12A33A, WET10A33A and 
WET12A33A. WET16A33A.
250V - 20A 6 - 20P 6
Model
Carton Dimensions
Height W i d t h  Depth
WallMaster
®
WSE Sleeve 18" 27 
1
/
4
" 18"
Chassis 19 
3
/
8
" 30 
5
/
8
" 27 
1
/
2
"
PLUG FACE/ CIRCUIT RATING