Submittal (2021)
Chassis requires WSE sleeve (sold and shipped separately)
Sleeve Dimensions
Friedrich 
WSE Sleeve
Fedders 
A Sleeve
Fedders 
B Sleeve
Height (inches) 16 3/4 16 3/4 16 3/4
Width (inches) 27 27 27
Depth (inches) 16 3/4 16 3/4 19 3/4
FITS EXISTING FEDDERS SLEEVES.
Height W id t h  Depth
Height of 
Front
Width of 
Front
Depth 
with 
Front
Minimum 
Extension Into Room 
with Front
Chassis 15 3/4" 26 1/2" 16 1/4" 17 1/4" 27 1/2" 23 1/4" 7 1/2"
CHASSIS DIMENSIONS
Model
Height W id t h  Depth
Depth 
with 
Front
Minimum 
Extension 
Outside
Thru-the-wall 
Finished Hole
Height Width Max. Depth
WSE Sleeve 16 3/4" 27" 16 3/4" 24 1/4"  9/16" 17 1/4" 27 1/4" 15 5/16"
WSE SLEEVE DIMENSIONS
Thru-the-wall_WallMaster_Submittal_2020
AG, Optional Architectural Grille
Premium brushed aluminum grille
WSE WALL SLEEVE
Standard Grille
Premium, stamped galvanized steel 
grille with powder coat paint. Ships 
with sleeve. Galvanized steel inner 
and outer weather panels also ship 
with sleeve.
OPTIONAL INSTALLATION ACCESSORIES
DK / Drain Kit
Installed at the back of the unit and allows for 
attachment to condensate disposal system, if 
necessary or desired.
IDK/ Internal Drain Kit
New construction applications 
where a condensate drain system 
has been built into the wall interior.
BAK / Bafe Adapter Kit
Necessary when installing 
in a sleeve deeper than 16 
3/4" deep, such as Fedders 
B sleeve (19 3/4" deep).
IMPORTANT: 
Operating the air conditioner 
with incorrect rear grille or 
without Bafe Adapter Kit 
(on 19 3/4” deep sleeve) will 
recirculate discharge air and 
cause compressor overload 
to trip. 
This will cause the unit 
to shut down temporarily 
and may lead to premature 
compressor failure.
CORRECT Vertical Louvers
INCORRECT Horizontal Louvers
INSTALLATION