User Manual
22 23
30°
45°
60°
30°
45°
60°
25ft
25ft
8ft
4ft
25ft
16ft
6ft
30°
30°
45°
60°
45°
60°
25ft
25ft
25ft
8ft
25ft
25ft
7.5ft
Figure 47
TOP VIEW
SIDE VIEW
FRR080
Remote Control Operation
Remote Control - Refer to Figure 47 during operation description.
Getting Started - Install two (2) AAA batteries in the battery compartment 
located on the back of the unit.
Operation - The remote control should be within 25 feet of the air conditioner 
for operation. (Refer to Figure 47 for effectiveness). Press the power button 
to turn the remote on. The remote will automatically power off after 15 
seconds if the buttons are not being pressed. The remote must be on to 
control the unit.
POWER Button - Turns remote and unit on and off.
SYSTEM Button - Allows the user to sequentially select the following: 
AUTO,  COOL,  HEAT, and FAN ONLY operations. When the button is 
pressed, the display indicates which mode has been selected via a display 
message. Note that when the heating function is not available, the system 
will automatically skip the HEAT mode.
FAN MODE Button - Selects between automatic (AUTO FAN) or 
CONTINUOUS operation. In the AUTO FAN mode, the fan only turns on 
and off when the compressor operates or the heat function is enabled.
NOTE:  AUTO FAN is not available in the FAN ONLY Mode, the display 
indicates CONTINUOUS. In the CONTINUOUS mode, fan speed 
is determined by your selection on the FAN SPEED button.
FAN SPEED Button - Used to sequentially select new fan speed, 
plus AUTO operation. When the FAN SPEED button is pressed, the 
fan speed icon (triangle) changes to indicate the new speed level. Fan 
speed automatically varies depending on the set temperature on the 
control  panel  and  the actual  room  temperature.  For example, if there 
is a big difference between your set temperature and the actual room 
temperature, the system fan speed increases to HIGH. It remains at 
this speed until the room temperature matches the set temperature.
UP and DOWN Arrows - Pressing either the UP or DOWN button 
changes the desired room temperature. The factory preset lower and 
upper limits are 60 °F (16 °C) and 99 °F (37 °C). These buttons are also 
used to navigate between function options when using the User Menu 
or Maintenance Mode.
Remote Effectiveness
Handheld Remote - Has an operating range of up to 25 ft. The infrared 
remote control signal must have a clear path to transmit the command to 
the air conditioning unit. The remote signal has some ability to “bounce” 
off of walls and furniture similar to a television remote control. The diagram 
below shows the typical operating range of the control in a standard room 
with 8 ft high ceilings.
Airflow Selection and Adjustment
Airflow direction adjustment
The airow path may be adjusted to distribute air independently from the 
left or right side of the discharge opening. Each of the banks of louvers can 
be directed left, right, up, or down in order to achieve the most optimum 
airow positioning.
To adjust airow direction, grab the lever in the center of the louver bank 
and move it in the direction that you would like the air to be directed. Please 
note that it is normal that airow may be stronger out of one side of the 
louvers than the other.
Control Panel Operation Instructions
SYSTEM - The MODE button allows you to sequentially select up to four 
modes of operation:
AUTO    Available on select models
COOL
HEAT  Available on select models
FAN ONLY
AUTO FAN (No Cooling Demand)
When in AUTO mode, the fan only operates when the system has a 
demand to cool or heat the room.
In the ON fan mode, the fan operates all the time. The system periodically 
cools or heats the fan’s airow but the ow of air does not stop.
UP and DOWN Arrows - Pressing either an UP or DOWN button changes 
the system’s setpoint (desired room temperature). These buttons are also 
used to make system parameter changes later in this manual.
One press equals 1 degree of change in Fahrenheit mode. One press 
equals 0.5 degree change in Celsius mode.
TIMER
The timer can be engaged or disengaged from the control panel. This is 
done by pressing or holding the UP and DOWN arrows simultaneously for 
three seconds.
OTHER FUNCTIONS
°F – °C  Select
To switch from degrees Fahrenheit (F) to Celsius (C), press the MENU 
button and enter the F-C sub-menu.
FAN SPEED - Depending on your model, the FAN SPEED button allows 
you to toggle between three or four modes of operation: LOW, MEDIUM, 
HIGH and MAX.
Alerts
When the lter needs to be cleaned or replaced, the CHECK FILTER 
icon displays.
The alert can be dismissed by pressing the FAN MODE and TIME for 
3 seconds.
Lock Control Panel
To lock/ unlock the front panel controls, navigate to the “LOCK” sub-menu 
found after clicking the MENU button. The lock requires a four digit pass code 
to lock/ unlock the unit. This pass code will be required to enter the menu to 
unlock the unit. The LOCK icon illuminates to indicate the locked status.
The LOCK icon disappears to indicate unlocked status.
External Control Status
The Wi-Fi icon illuminates to indicate that the system is receiving a Wi-
Fi connection. The Wi-Fi icon also provides information about the signal 
strength.
ADVANCED FUNCTIONS
The functions mentioned in the following section may or may not be available 
depending on the air conditioner model.
Modify the TIMER Function
Navigate to the TIME menu to set the timer.