Submittal (2021)
Uni-Fit
®
Model Number
Circuit 
Rating
Breaker
or T-D Fuse
Plug 
Face
(NEMA#)
Power 
Cord 
Length 
(ft.)
Wall
Outlet
Appearance
UCT08A10A, UCT10A10A, 
UCT12A10A 
125V - 15A 5 - 15P 6
UCT10A30A, UCT12A30A, 
UCT14A30A
250V - 15A 6 - 20P 6
UE T08A11A 125V - 15A 5 - 15P 4.75
UET10A33A, UET12A33A, 
UET14A33A
250V - 20A 6 - 20P 4.75
Thru-the-wall_Air_Conditioners_Uni-Fit_Submittal_2021
LISTED
ROOM AIR CONDITIONERS
183H
ENERGY STAR
®
 models
SPECIFICATIONS
CARTON DIMENSIONS
PLUG FACE/CIRCUIT RATING
Estar
Model UPC
 Cooling 
Btu
 Heating 
Btu
Volts 
Rated
 Cooling 
Amps
Cooling 
Watts
Heating 
Amps
Heating
Watts EER CEER
Estimated 
Yearly 
Energy
 Cost
Moisture
Removal
Pints/Hr Refrigerant CFM Sleeve
Net 
Weight 
Lbs
Ship 
Weight 
Lbs
UNI-FIT
®
Cool Only
UCT08A10A 724587436747 8000 — 115 6.9 755 — — 10.7 10.6 $69 0.8 R410A 265 64 78
UCT10A10A 724587436754 10000 — 115 8.3 940 — — 10.7 10.6 $85 1.25 R410A 247 74 86
UCT10A30A 724587436938 10000 — 230 4.5 940 — — 10.7 10.6 $85 1.25 R410A 265 74 86
UCT12A10A 724587436761 12000 — 115 10.1 1130 — — 10.6 10.5 $102 1.7 R410A 276 75 88
UCT12A30A 724587436778 12000 — 230 5.4 1130 — — 10.6 10.5 $102 1.7 R410A 265 75 88
UCT14A30A 724587436785 14000 — 230 7.2 1490 — — 9.4 9.3 $135 2.15 R410A 265 76 89
Cool with Electric Heat
UET08A11A 724587436792 8000 4200 115 7.2 810 12.5 1320 9.7 9.6 $74 0.75 R410A 265 66 79
UET10A33A 724587436808 10000 10600 230 4.9 1030 15 3500 9.7 9.6 $93 1.2 R410A 276 75 87
UET12A33A 724587436815 12000 10600 230 5.9 1230 15 3500 9.7 9.6 $111 1.65 R410A 276 76 89
UET14A33A 724587436822 14000 10600 230 7.2 1490 15 3500 9.4 9.3 $135 2.15 R410A 265 77 90
Power cords are located on front left of Uni-Fit models.
Model
Carton Dimensions Inches
Height Width  Depth
Uni-Fit
®
USC Sleeve
17 
7
/
8
"
28"
19 
1
/
4
"
UCT, UET Chassis 16 
3
/
8
" 27 
3
/
4
" 26 
5
/
8
 "