Non-Programmable Electronic Thermostat Installation, Operation & Application Guide

2
Specifications
Input:
Voltage: 18-30 VAC
Output:
Maximum: 1 amp per terminal (3 amp total for all terminals)
Temperature Ranges:
Temperature control range: 45°F to 90°F (7°C to 32°C) Accuracy: ± 1°F (± 0.5°C)
Differential range: 1°F to 3°F (0.5°C to 1.5°C) Accuracy: ± 1°F (± 0.5°C)
System configurations: Single stage heat pump
Terminations: R, C, W, Y, B, O, G
Note: This thermostat is designed for: Single stage electric
heating, heating/cooling systems and heat pump
systems. It will retain your setpoint temperatures in
memory for up to 30 minutes during a power outage.
SET
ROOM
DIFF
Temperature
differential setting
Room temperature
Room temperature
setpoint
Important Safety Information
Always turn off the thermostat before installing, removing, cleaning, or servicing; turn off the power at the main
power source by unscrewing fuse or switching off circuit breaker
Do not switch to “Cool” if outside temperature is below 50
°
F (10
°
C), this could damage your A/C system and cause
injury
Do not install on voltages higher than 30 VAC
All wiring must conform to local and national building and electrical codes and ordinances
While cleaning, do not get soap directly on thermostat switches or LCD readout; only use a damp cloth with a mild
soap to wipe the outside of the thermostat cover