Submittal (2020)
230/208V Fresh Air Inverter
COOLING
PVH09K
STANDARD RATING  9600/9400 Btu 
EXTENDED RATING  6,462 - 12099 Btu
PVH12K
STANDARD RATING  12000/11800 Btu
EXTENDED RATING  7,929 - 17142 Btu
Up to 12.9 EER
Up to 15.0 Equivalent SEER
HEAT PUMP
PVH09K
STANDARD RATING  8200/8500 Btu
EXTENDED RATING  5606 - 11745 Btu
PVH12K
STANDARD RATING  11600/11800 Btu
EXTENDED RATING  6995 - 16187 Btu
Up to 11.57 Application HSPF
BACK UP ELECTRIC HEAT
2.5 kw, 3.5 kw and 5.0 kw* 
heater options
*5.0 kw heater cannot be used 
on PV09K/PV09R
265V Fresh Air Inverter
COOLING
PVH09R
STANDARD RATING  9600 Btu 
EXTENDED RATING  6,462 - 12099 Btu
PVH12R
STANDARD RATING  12000 Btu
EXTENDED RATING  7,929 - 17142 Btu
Up to 12.0 EER
HEAT PUMP
PVH09R
STANDARD RATING  8500 Btu
EXTENDED RATING  5606 - 11745 Btu
PVH12R
STANDARD RATING  11800 Btu
EXTENDED RATING  6995 - 16187 Btu
Up to 3.57 COP
FRESHAIRE EXTENDED CAPACITY RANGE
Make-up air 
passes through 
Merv 8 filter, 
then mixes with 
return air.
Return air
Patented technology uses the inverter 
compressor and main cooling system to 
optimize temperature and humidity level of 
incoming air. 
By introducing make-up air directly into the 
guestroom, rooftop central fresh air systems 
can be considerably downsized to service 
only the common areas of the property. 
This greatly reduces the cost and complexity 
of hotel design and construction. Unlike 
other PTACs, the FreshAire PTAC utilizes 
the main evaporator coil and Merv 8 lters 
to truly condition and lter the outside 
ventilation air.
FreshAire system helps achieve ASHRAE 62.1-2013 requirements, and brings up to 52 CFM 
of conditioned, MERV 8 filtered, outside air into the space. 
Friedrich's proprietary Freshaire™ design and deliv-
ery system is protected under US Patent#10.436.457 
PTAC FreshAire Series Submittal_ 2020