Product Profile (2020)

Table Of Contents
2
ONLY TWO MODELS
With only two models in both 230/208V and two in 265V ranging from 6000btu 17000btu, the FreshAire
PTAC meets your needs without the complicated buying decisions.
BETTER
DEHUMIDIFICATION
With longer run times, the indoor coil stays colder longer resulting in better overall dehumidication
outside of standard conditions.
SOFT START
OPERATION
With the benet of an inverter compressor there is no longer a sudden and noisy start up of compressors.
Compressor starts up slowly gradually ramping up to the required speed to control the conditioned space.
REMOTE THERMOSTAT
OPERATION
Some applications require the use of a wall-mounted thermostat. All-new FreshAire PTACs may be
switched from unit control to remote thermostat control easily without the need to order a special model
or accessory kit.
INTERNAL DIAGNOSTIC
PROGRAM
The FreshAire PTAC features a self-diagnostic program that can alert maintenance to component failures
or operating problems. The internal diagnostic program saves properties valuable time when diagnosing
running problems.
SERVICE ERROR CODE
STORAGE
All FreshAire PTAC units have self-diagnostic features that will store trouble codes in the case of an event.
Storing the codes allows the property to see the trouble codes at a future time after the condition may
have corrected.
ELECTRONIC
TEMPERATURE
LIMITING
By limiting the operating range, the property can save energy by eliminating “max cool” or “max heat
situations common with older, uncontrolled systems. The new electronic control allows owners to set
operating ranges for both heating and cooling independently of one another.
ROOM FREEZE
PROTECTION
When the PTAC senses that the indoor room temperature has fallen to 40
°
F, the unit will cycle on the
fan (high) and the electric strip heat to raise the room temperature to 46
°
F, and then cycle o󰀨 again. This
feature works regardless of the mode selected and can be turned o󰀨. The control will also store the Room
Freeze cycle in the service code memory for retrieval at a later date. This feature ensures that unoccupied
rooms do not reach freezing levels where damage can occur to plumbing and xtures.
CONDENSATE REMOVAL
SYSTEM
Condenser fan utilizes slinger ring technology to pick up condensate from the base pan and disperse it on
to the condenser coil where it evaporates. This helps to cool the coil and increase the energy e󰀩ciency
of the unit.
SUPERIOR OPERATION
AND CONTROL
Paired with Friedrich VRPXEMRT2 control, designed for use with the FreshAire PTAC, maximizes full
inverter compressor control, enhances humidity and dehumidication control, and optimizes comfort.