90 PB
TROUBLESHOOTING
Unit Does Not Operate
Disconnect Dis play
Connector CN6 on
top of Main PCB
Set multi meter do
read low voltage DC
and pl ace Mult i
Meter leads on pins
3 and 7.
Is Fluctuating
0-6Vdc Present?
Set multimeter to
read continuity.
Check all wires on
display boar d
conne ct or c ab le to
CN6 plug for pin to
pin continuity.
Are any wi re s
showing open
(OL)?
Replace Dis play
Boa rd
Replace Connector
cabl e
Che ck all wi r ing an d
comms cable
conne ct or s from
Mai n PCB to the
Power PCB
Ensure all
conne ct or s are
undama ged, ful ly
connected and fully
engaged.
Fix any issues
Refere nc e wiring di agr am (figure 801)
Main PCB Diagram (Figure 7xx)
Power P CB Di agra m (Figure (7 xx )
Any loose,
damaged, or
disconnected
conne ct or s?
Is Fluctuating
0-6Vd c Pre sent?
NO YES
YES
YES
END PROCESS YES
No
Continue
troubleshooting on
next page
No
NO
Figure 713