Product Profile (2021)

6
ELECTRIC HEAT DATA
EXTENDED HEATING PERFORMANCE
OUTDOOR DRY BULB TEMP. (DEGREES F)
37 42 47 52 57
PVH09K
BTUH 6833 7211 8200 8981 9918
WATTS 670 681 710 722 762
AMPS 3.9 4 4 4.1 4.3
PVH12K
BTUH 8747 9322 11800 12597 13467
WATTS 871 884 970 977 990
AMPS 4.5 4.5 4.6 4.6 4.7
PVH09R
BTUH 6138 6777 8500 8959 9719
WATTS 621 645 710 731 755
AMPS 3.2 3.3 3.6 3.8 3.9
PVH12R
BTUH 9342 9626 11800 12909 14142
WATTS 893 905 970 1028 1074
AMPS 3.9 4.0 4.3 4.5 4.7
RATING POINT
ARI 310/380
ELECTRIC HEAT DATA
Model PVH09K PVH09K PVH12K PVH12K PVH12K
Power Cord PXPCFA23015 PXPCFA23020 PXPCFA23015 PXPCFA23020 PXPCFA23030
Heater Watts 2500/2405 3500/2863 1500/1227 3500/2863 5000/4090
Voltage 230/208 230/208 230/208 230/208 230/208
Heating BTU 8500 11900 5100 11900 17000
Heating Current (amps) 10.9/12.1 15.3/16.9 6.6/7.3 15.3/16.9 21.8/24.1
Minimum Circuit Ampacity 13.9 19.3 8.46 19.3 27.5
Maximum Over Current Protection
(MOP/MOCP)/Branch Circuit Fuse (amps)
15 20 15 20 30
ELECTRIC HEAT DATA
Model PVH09R PVH09R PVH12R PVH12R PVH12R
Power Cord PXPCFA26515 PXPCFA26520 PXPCFA26515 PXPCFA26520 PXPCFA26530
Heater Watts 2500/2045 3500/2863 1500/1227 3500/2863 5000/4090
Voltage 265 265 265 265 265
Heating BTU 8500 11900 5100 11900 17000
Heating Current (amps) 9.5 13.3 5.7 13.3 18.9
Minimum Circuit Ampacity 12 16.8 7.3 16.8 23.8
Maximum Over Current Protection (MOP/
MOCP)/Branch Circuit Fuse (amps)
15 20 15 20 30