Installation & Operation Manual (2019, 2020, 2022)
Table Of Contents
- Table of Contents
- Congratulations
- General Instructions
- WARNING
- WARNING
- Read Installation Operation Manual
- General Specifications
- Typical Unit Components and Dimensions
- Installation Checklist
- PTAC Installation Recommendations
- For proper PTAC unit performance and maximum opera
- For PTACs on the ground floor or anytime obstructi
- Wall Sleeve Installation Instructions (PDXWSA)
- WARNING
- Falling Object Hazard
- Alternate Wall Installations
- One-Piece Deep Wall Sleeve Installation (PDXWSEXT
- PXDR10 Drain Kit Installation Instructions (option
- Internal Drain
- FRONT VIEW
- Drain Tube Installation (See Figure 12)
- Cover Plate Installation
- DETAIL B
- PXGA Standard Grille Installation Instructions
- WARNING
- Falling Object Hazard
- Electrical Rating Tables
- All units are equipped with standard power cords.
- Electrical Shock Hazard
- Power Cord Information (230/208V models only)
- Electrical Wiring for 265 Volt Models
- Power Cord Installation
- To install the line voltage power leads and condu
- Electrical Shock Hazard
- Chassis Install Preparation
- Check to be sure the wall sleeve, extension (if us
- Suffocation Hazards
- CAUTION
- Unit Damage Hazard
- Chassis Installation
- Excessive Weight Hazard
- Friedrich PTAC Digital Control and Unit Features
- System Configuration
- Fresh Air Vent Control
- Adjusting Air
- Digital Control User Input Configuration
- Dip Switch Setting
- Dip Switches
- Digital Control Operation
- Heat Pump Models (PVH)
- Constant Fan
- Settings- Detailed Configurations
- Remote Control Thermostat Installation
- Install Thermostat
- The Thermostat should NOT be mounted:
- To control the unit with a wall mounted thermosta
- Thermostat Connections
- Electrical Shock Hazard
- Final Inspection & Start-up Checklist
- WARNING
- Basic Troubleshooting
- Error code and solutions
- Accessories
- PV-SERIES
14
TABLE 2
MODEL
HEATER kW
Power Cord Kit
Voltage
Amperage
Receptacle
PVH09K
2.5(optional)
STD
230/208
15
NEMA 6-15r
3.5(default)
STD
230/208
20
NEMA 6-20r
PVH12K
1.5(optional)
STD
230/208
15
NEMA 6-15r
3.5(default)
STD
230/208
20
NEMA 6-20r
5.0(optional)
STD
230/208
30
NEMA 6-30r
PVH09R
2.5(optional)
STD
265/277
15
NEMA 7-15r
3.5(default)
STD
265/277
20
NEMA 7-20r
PVH12R
1.5(optional)
STD
265/277
15
NEMA 7-15r
3.5(default)
STD
265/277
20
NEMA 7-20r
5.0(optional)
STD
265/277
30
NEMA 7-30r
Electrical Wiring for 265 Volt Models
Power Cord Installation
All 265V PTAC/PTHP units come with a factory installed non-LCDI
power cord for use in a subbase.If the unit is to be hard-wired refer to
the instructions below.
NOTE: It is recommended that the PXSB subbase assembly, the
PXCJA conduit kit(or equivalent) be installed on all
hardwire units.If installing a flush-floor mounted unit,make
sure the chassis can be removed from the sleeve for
service and maintenance.
Toinstall the line voltage power leads and conduit to
chassis, follow the instructions below . PXCJA
ConduitKit is required with this setup.
1. Follow the removal process of the chassis’s junction box .
2. Prepare the 265V(or 230V)power cord for connection to the chassis’
power cord connector by cutting the cord to the appropriate length
(refer to Figure16 and follow Figure15).Power cord harness selection
shown on Table 2 on page 14.
WARNING
Electrical Shock Hazard
Turn off electrical power before service
or installation.
ALL electrical connections and wiring
MUST be installed by a qualified
electrician and conform to the National
Code and all local codes which have
jurisdiction.
Failure to do so can result in property