Service and Parts Manual (2016, 2017, 2018, 2019, 2020, 2021, 2022)

Table Of Contents
12 PB
SPECIFICATIONS
General Specications 12-15k Electric Heat
PTAC Electric Heat models
PDE12K PDE12R PDE15K PDE15R
PERFORMANCE DATA:
Cooling Btu 11800/11600 11800 14500/14200 14500
Cooling Watts 1015/1000 1015 1390/1365 1390
Energy Efciency Ratio, EER 11.6/11.6 11.6 10.4/10.4 10.4
Moisture Removal (pints/hr.) 2.7 2.7 3.1 3.1
Sensible Heat Ratio 0.75 0.75 0.67 0.67
ELECTRICAL DATA:
Voltage (1 PHASE, 60 Hz) 230/208 265 230/208 265
Volt Range 253-187 292-239 253-187 292-239
Current (Amps) 4.9/5.1 4.2 6.2/6.7 5.4
Power factor 0.97 0.97 0.97 0.97
Compressor LRA 21.5 19.0 28.9 21.6
Compressor RLA 4.7 3.9 5.9 5.05
Outdoor Fan Motor, HP 0.086 0.086 0.086 0.086
AIRFLOW DATA:
Indoor CFM, HIGH 400/390 400 400/390 400
Indoor CFM, LOW 325/310 325 325/310 325
Vent CFM 75 75 75 75
PHYSICAL DATA:
Sleeve Dimensions (H x W x D) 16” x 42” x 13 3/4” (all models)
Dimensions with Front (H x W x D) 16”x 42”x 21 1/2” (all models)
Cut Out Dimensions (H x W x D) 16 1/4”x 42 1/4” (all models)
Net Weight (lbs.) 119 118 121 121
Shipping Weight (lbs.) 139 138 140 140
R-410A CHARGE (oz.) 36 36 36 36
Figure 203 (General Specs)