Service and Parts Manual (2016, 2017, 2018, 2019, 2020, 2021, 2022)

Table Of Contents
10 PB
SPECIFICATIONS
General Specications 7-9k Electric Heat
Figure 201 (General Specs)
PTAC Electric Heat models
PDE07K PDE07R PDE09K PDE09R
PERFORMANCE DATA:
Cooling Btu 7200/7000 7200 9400/9200 9400
Cooling Watts 550/535 550 775/760 775
Energy Efciency Ratio, EER 13.0/13.0 13.0 12.1/12.1 12.1
Moisture Removal (pints/hr.) 1.7 1.7 2.1 2.1
Sensible Heat Ratio 0.86 0.86 0.85 0.85
ELECTRICAL DATA:
Voltage (1 PHASE, 60 Hz) 230/208 265 230/208 265
Volt Range 253-187 292-239 253-187 292-239
Current (Amps) 2.7/2.9 2.4 3.7/3.9 3.3
Power factor 0.97 0.97 0.97 0.97
Compressor LRA 13.0 12.5 19.5 13.5
Compressor RLA 2.5 2.2 3.5 3.0
Outdoor Fan Motor, HP 0.080 0.080 0.080 0.080
AIRFLOW DATA:
Indoor CFM, HIGH 345/315 345 355/325 355
Indoor CFM, LOW 270/255 270 300/275 300
Vent CFM 75 75 75 75
PHYSICAL DATA:
Sleeve Dimensions (H x W x D) 16” x 42” x 13 3/4” (all models)
Dimensions with Front (H x W x D) 16”x 42”x 21 1/2” (all models)
Cut Out Dimensions (H x W x D) 16 1/4”x 42 1/4” (all models)
Net Weight (lbs.) 106 107 115 115
Shipping Weight (lbs.) 126 127 135 135
R-410A CHARGE (oz.) 23 23 24 24