Brochure

AUTO CLEAN
Indoor blower runs to remove dust, dirt and moisture
from the coil after system is shutdown.
SURGE COOL/HEAT
Allows quick cooling/heating. In this mode, the unit will
operate at 100% for 30 minutes to cool/heat the room
rapidly.
BUILT-IN LOW AMBIENT STANDARD
Allows wall-mounted units to operate in temperatures
as low as 14º F in cooling mode (HM09YJA and HM12YJA
as low as 0º F). Concealed ducted and cassette models
can operate down to 5º F.
AUTO CHANGEOVER (SINGLE ZONE ONLY)
Automatically changes over from cool to heat and heat
to cool to maintain the set temperature.
AUTO RESTART
Auto restart function allows system to resume with
previous settings in the event of a power shutdown.
(Power supply must be restored).
DRY MODE
Reduces the humidity when cooling needs are low.
4-WAY AUTO SWING
Louvers will automatically move up/down and left /right to
maintain a uniform room temperature.
ADVANCED CORROSION PROTECTION
Protects the outdoor coil against deterioration and
extends the life of the unit especially in harsh coastal
environments.
Features you'll find with Friedrich Ductless Systems:
System Type
Wall-mounted
Single Zone
Wall-mounted
Multizone
Cassette
Single Zone
Cassette
Multizone
The Insider
Single Zone
The Insider
Multizone
Installation Wall Wall Ceiling Ceiling Ceiling Ceiling
Cool only Y N N N N N
Heat pump Y Y Y Y Y Y
115 volt cool only models Y N N N N N
Inverter driven compressor Y Y Y Y Y Y
SEER Up to 28.0 Up to 22.0 Up to 19.0 Up to 22.0 Up to 17.6 Up to 18.2
Auto changeover Y N Y N Y N
Low ambient cooling operation 0° F*/ 0° F
-4° F** 5° F -4° F** 5° F -4° F **
Low ambient heating operation -4° F /-13° F
-4° F -4° F -4° F -4° F -4° F
24- Hr. Programmable timer Y Y Y Y N N
Remote control Y Y Y Y N N
Wall controller option Y Y Y Y Y Y
7-Day Programmability
(with wall controller) Y Y Y Y Y Y
Auto restart Y Y Y Y Y Y
Surge cool/heat Y Y Y Y N N
Dry mode Y Y Y Y Y Y
Auto Clean Y Y N N N N
Advanced Corrosion Protection Y Y Y Y Y Y
4-way auto swing Y Y Y Y N N
Washable, antimicrobial air lters Y Y Y Y Y Y
Auto shut aps when unit is off Y Y Y Y N N
Louver Position Steps (Fan/Cool/Heat) 6 / 6 / 6 6 / 6 / 6 4 / 5 / 4 4 / 5 / 4 N N
*Installation of an optional Low Ambient Wind Bafe Kit will allow operation down to 0°F in cooling mode.
HM09YJA and HM12YJA operate down to 0°F cooling and -13°F heating without wind bafe kit.
**Installation of an optional Low Ambient Wind Bafe Kit will allow operation down to -4°F in cooling mode.
8 | FRIEDRICH J SERIES DUCTLESS