Brochure
PERFORMANCE RATINGS Multizone - The Insider
™
Concealed Ducted Heat Pumps
9k 12k 18k
INDOOR MODEL MD09Y3JM MD12Y3JM MD18Y3JM
SPECIFICATIONS
CAPACITY COOLING (RATED) Btu 9,000 12,000 18,000
CAPACITY HEATING (RATED) Btu 10,400 13,800 19,000
MOISTURE REMOVAL Pts/h 2.5 2.5 4.2
AIRFLOW ( LOW, MED, HIGH) CFM 194 / 247 / 318 265 / 300 / 335 406 / 477 / 530
SOUND RATING - INDOOR dB-A 30 / 26 / 23 26/31/33 29/31/34
ELECTRICAL DATA
POWER SOURCE 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60
POWER AND COMMUNICATION CABLE No. x AWG 4 x 14 4 x 14 4 x 14
REFRIGERATION SYSTEM
CONNECTIONS Flare Flare Flare
LIQUID LINE O.D. in 1/4 1/4 1/4
SUCTION LINE O.D. in 3/8 3/8 1/2
DIMENSIONS & WEIGHT
W X H X D in
30-15/32 x 7-15/32 x 27
-
9/16
32-9/32 x 7-15/32 x 22-5/8 43-5/16 x 7-15/32 x 22-5/8
NET WEIGHT lbs 39 45 58
SHIPPING WEIGHT lbs 45 51 65
SPECIFICATIONS
*System requires branch box D4PBB. See page 33 for piping guidelines. For branch box to indoor line sizes, please see Indoor System Components Chart.
Your operating costs will depend on your utility rates and use. The estimated operating cost is based on a electricity cost of $ .12 per kWh. For more
information, visit www.ftc.gov/energy.
Due to continuing research in new energy-saving technology, specications are subject to change without notice.
PERFORMANCE RATINGS Multi Outdoor
24k 36k 48k
OUTDOOR MODEL MR24DY3JMA MR36TQY3JMA MR48DEY3JM
SPECIFICATIONS
POWER SOURCE 208/230/60/1 208/230/60/1 208/230/60/1
EST. YEARLY OPERATING COST $ 122~125 170~245 346~400
RUNNING CURRENT COOLING MIN.~RATED~MAX. A 1.7~6.4~9.0 2.9~10.7~15.7 4.6~16.7~24.8
RUNNING CURRENT HEATING MIN.~RATED~MAX. A 1.8~7.8~11.2 3.3~11.9~18.3 6.2~18.8~26.2
POWER INPUT COOLING MIN.~RATED~MAX. W 390~1480~2070 670~2460~3610 970~3840~5710
POWER INPUT HEATING MIN.~RATED~MAX. W 420~1800~2580 760~2740~4210 1420~4320~6020
POWER AND COMMUNICATION CABLE No. x AWG 4 X 14 4 X 14 4 X 14
DIMENSIONS W X H X D inch
34-1/4 x 25-3/4 x12-5/8 37-7/16 x 32-7/8 x 15 1/2 37-3/8 × 54-5/16 × 13
NET WEIGHT lbs 99 137 214
SHIPPING WEIGHT lbs 139 148 236
REFRIGERATION SYSTEM
REFRIGERANT R410A R410A R410A
FACTORY PRECHARGE ft 74 98 Main 16.4, Branch 131.2
LIQUID LINE O.D. in 1/4 1/4 3/8
SUCTION LINE O.D. in 3/8 3/8 3/4
MIN./MAX. LINE LENGTH (EACH) ft 10~82 10~82 10~49*
MIN./MAX. LINE LENGTH (TOTAL) ft 75~246 75~246 30~475*
MAX. HEIGHT DIFFERENCE ft 49 49 98*
SOUND PRESSURE LEVEL COOLING A 51 52 54
SOUND PRESSURE LEVEL HEATING A 51 55 56
OPERATING RANGE COOLING (WIND BAFFLE) °F DB 14 (-4) ~ 118 14 (-4) ~ 118 14 (-4) -118
OPERATING RANGE HEATING °F WB -4 ~ 64 -4 ~ 64 -4 ~ 64
MINIMUM AMPACITY A 14.3 17.9 27.3
MAX. TD FUSE/BREAKER A 20 25 40
27