Brochure

PERFORMANCE RATINGS Single Zone Wall-Mounted - Heat Pumps
18k 24k 36k
SYSTEM MODEL NO. M18YJ M24YJ M36YJ
INDOOR MODEL MW18Y3J MW24Y3J MW36Y3J
OUTDOOR MODEL MR18Y3J MR24Y3J MR36Y3J
SPECIFICATIONS
CAPACITY COOLING (RATED) Btu 17,000 22,000 33,000
CAPACITY COOLING (MIN~MAX) Btu 3,070~20,470 3,070~30,030 3,070~34,000
CAPACITY HEATING
@
47
0
F (RATED) Btu 20,200 27,000 35,200
CAPACITY HEATING
@
17
0
F (RATED) Btu 13,200 17,900 23,200
CAPACITY HEATING (MIN~MAX) Btu 3,070~30,700 3,070~38,898 3,070~38,900
COOLING AMPS 7 7.9 17.0
HEATING AMPS 7.3 10.7 16.2
SENSIBLE HEAT RATIO .73 .72 .78
SEER 18.0 21.5 17.5
EER 12.0 12.5 8.15
HSPF 9.7 11.0 10.0
ENERGY STAR YES YES No
MOISTURE REMOVAL Pts/h 4.2 5.5 6.5
AIRFLOW (QUIET, LOW, MED, HIGH) CFM 300/371/441/512 300/389/512/600 459/530/706/848
SOUND RATING - INDOOR dB-A 29 / 35 / 40 / 45 33 / 39 / 43 / 46 37 / 40 / 44 / 49
SOUND RATING - OUTDOOR dB-A 53 54 55
OPERATING RANGE COOLING (WIND BAFFLE) °F 14(0)~118 14(0)~118 14(0)~118
OPERATING RANGE HEATING °F -4~75 -4~75 -4~75
EST. YEARLY OPERATING COST $ 127 158 395
ELECTRICAL DATA
POWER SOURCE V 230/208/60/1 208/230/60/1 230/208/60/1
MINIMUM AMPACITY A 19 19 19
COOLING WATTS W 1416 1760 4024
HEATING WATTS W 1680 2380 3840
MAX. TD FUSE/BREAKER A 20 35 35
POWER AND COMMUNICATION CABLE
No. x AWG
4 x 14 4 x 14 4 x 14
REFRIGERATION SYSTEM
REFRIGERANT R410A R410A R410A
COMPRESSOR TYPE Twin Rotary Twin Rotary Twin Rotary
CONNECTIONS Flare Flare Flare
LIQUID LINE O.D. in 1/4 3/8 3/8
SUCTION LINE O.D. in 1/2 5/8 5/8
FACTORY PRECHARGE ft 25 25 25
REFRIGERANT CHARGE oz 48 78 78
MIN./MAX. LINE LENGTH ft 10~66 10~164 10~164
MAX. HEIGHT DIFFERENCE ft 33 98 98
DIMENSIONS & WEIGHT
INDOOR UNIT
W X H X D in 40-5/8 x 12-7/8 x 9-5/8 46-7/8 x 13-5/8 x10-3/8 46-7/8 x 13-5/8 x 10-3/8
NET WEIGHT lbs 31 40 40
SHIPPING WEIGHT lbs 40 46 46
OUTDOOR UNIT
W X H X D in 34-5/16 x 25-7/8 x 12-5/8 34-5/16 x 31-1/2 x12-5/8 34-5/16 x 31-1/2 x12-5/8
NET WEIGHT lbs 97 125 125
SHIPPING WEIGHT lbs 101 132 132
TOTAL NET WEIGHT lbs 128 165 165
TOTAL SHIPPING WEIGHT lbs 141 178 178
Your operating costs will depend on your utility rates and use. The estimated operating cost is based on a electricity cost of $ .12 per kWh.
For more information, visit www.ftc.gov/energy.
Due to continuing research in new energy-saving technology,
specications are subject to change without notice.
SPECIFICATIONS