Brochure
PERFORMANCE RATINGS Single Zone Wall-Mounted - Cool Only
9k 12k 18k
SYSTEM MODEL NO.
M09CJ M12CJ M18CJ*
INDOOR MODEL MW09C1J MW12C1J MW18C3J*
OUTDOOR MODEL MR09C1J MR12C1J MR18C3J*
SPECIFICATIONS
CAPACITY COOLING (RATED) Btu 9,000 10,600 17,000
CAPACITY COOLING (MIN~MAX) Btu 3,070~12,120 3,070~13,660 3,070~20,470
COOLING AMPS 6 7.3 6.3
SENSIBLE HEAT RATIO .71 .71 .72
SEER 21.5 21.5 18.0
EER 13.3 13.0 12.0
ENERGY STAR YES YES NO
MOISTURE REMOVAL Pts/h 2.3 2.7 4.2
AIRFLOW (QUIET, LOW, MED, HIGH) CFM 124/212/272/335 124/212/272/335 300/371/441/512
SOUND RATING - INDOOR dB-A 19 / 24 / 33 / 38 19 / 24 / 33 / 39 29 / 35 / 40 / 45
SOUND RATING - OUTDOOR dB-A 45 45 53
OPERATING RANGE ( 0°F WITH WIND BAFFLE) °FDB 14(0)~118 14(0)~118 14(0)~118
EST. YEARLY OPERATING COST $ 61 81 127
ELECTRICAL DATA
POWER SOURCE V 115/60/1 115/60/1 208/230/60/1
MINIMUM AMPACITY A 12 12 19
COOLING WATTS W 677 815 1417
MAX. TD FUSE/BREAKER A 20 20 25
POWER AND COMMUNICATION CABLE
No. x AWG
4 x 14 4 x 14 4 x 14
REFRIGERATION SYSTEM
REFRIGERANT R410A R410A R410A
COMPRESSOR TYPE Single Rotary Single Rotary Twin Rotary
CONNECTIONS Flare Flare Flare
LIQUID LINE O.D. in 1/4 1/4 1/4
SUCTION LINE O.D. in 3/8 3/8 1/2
FACTORY PRECHARGE ft 41 41 25
REFRIGERANT CHARGE oz 36 36 48
MIN./MAX. LINE LENGTH ft 7~66 7~66 10~66
MAX. HEIGHT DIFFERENCE ft 33 33 33
DIMENSIONS & WEIGHT
INDOOR UNIT
W X H X D in
35-1/4 x 11-1/4 x 8-5/16 40-5/8 x 12-7/8 x 9-5/8
NET WEIGHT lbs 23 23 32
SHIPPING WEIGHT lbs 27 27 40
OUTDOOR UNIT
W X H X D in
30-5/16 x 21-5/16 x 11-5/16 34-5/16x 25-7/8 x12-5/8
NET WEIGHT lbs 78 78 97
SHIPPING WEIGHT lbs 79 79 101
TOTAL NET WEIGHT lbs 101 101 129
TOTAL SHIPPING WEIGHT lbs 106 106 169
SPECIFICATIONS
*Models M18CJ and components MW18C3J and MR18C3J are not available for sale in AZ, CA, NM or NV.
Your operating costs will depend on your utility rates and use. The estimated operating cost is based on a electricity cost of $ .12 per kWh.
For more information, visit www.ftc.gov/energy.
Due to continuing research in new energy-saving technology, specications are subject to change without notice.
13