Kuhl Submittal 2018
LISTED
ROOM AIR CONDITIONERS
183H
SPECIFICATIONS
Indicates ENERGY STA R
®
models
Model Cooling Btu Heating Btu Volts
Cooling
Amps Cooling Watts
Heating
Amps Heating Watts EER CEER
Estimat-
ed Yearly
Energy
Cost COP
Moisture
Removal-
Pints/HR CFM
Kühl
®
(Cool Only)
SQ06N10C 5800 — 115 4.1 472 — — 12.3 12.1 $43 — 1. 5 190
SQ08N10D 8000 — 115 6.1 656 — — 12.2 12.0 $59 — 1. 9 200
SQ10N10C 10000 — 115 8.9 882 — — 11. 1 10.9 $79 — 3.2 250
SS08N10C 8000 — 115 5.8 656 — — 12.2 12.0 $59 — 1. 9 255
SS10N10C 10000 — 115 7. 2 820 — — 12.2 12.0 $74 — 2.5 300
SS12N10C 11900 — 115 8.7 975 — — 12.2 12.0 $88 — 3.9 300
SS12N30C 12000/11800 — 230/208 4.5/4.9 984/967 — — 12.2/12.2 12.0/12.0 $89 — 3.6 300
SS14N10C 13600 — 115 10.4 1214 — — 11.2 10.9 $109 — 4.3 275
SS16N30C 15500/15300 — 230/208 6.5/7.1 1435/1417 — — 10.8/10.8 10.7/10.7 $129 — 5.0 330
SM14N10 13700 — 115 9.9 112 3 — — 12.2 12.0 $101 — 3.0 360
SM18N30C 20000/20000 — 230/208 9.3/10.2 2092/2041 — — 10.3/10.3 10.3/10.3 $184 — 6.0 425
SM21N30E 20500/20500 — 230/208 9.3/10.2 2092/2041 — — 10.3/10.3 10.3/10.3 $188 — 6.0 425
SL24N30C 24000/24000 — 230/208 10.2/11.1 2308/2308 — — 10.4/10.4 10.3/10.3 $208 — 7. 0 640
SL28N30C 28000/28000 — 230/208 13.1/14.1 2800/2800 — — 10.0/10.0 9.9/9.9 $252 — 8.5 640
SL36N30B 36000/35500 — 230/208 17.5/19.2 4000/3944 — — 9.0/9.0 9.0/9.0 $360 — 12.0 725
Kühl
®
+ (Heat Pump)
YS10N10C* 10000 8800 115 7. 9 917 9.0 978 10.9 10.8 $83 2.6 2.0 300
YS12N33C 12000/12000 11300/11000 230/208 4.9/5.2 1101/ 1101 5.6/5.9 1257/1213 10.9/10.9 10.8/10.8 $99 2.6/2.7 3.0 375
YM18N34C 17500/17200 15200/15200 230/208 7.1/7.6 1606/1578 7.3/8.0 1665/1665 10.9/10.9 10.8/10.8 $149 2.7/2.7 5.4 370
YL24N35D 24000/24000 22000/22000 230/208 10.1/11.0 2330/2330 10.7/11.4 2391/2391 10.3/10.3 10.2/10.2 $210 2.6/2.6 7. 0 600
Kühl
®
+ (Electric Heat)
EQ08N11D 8000 4000 115 6.1 656 11. 2 1290 12.2 12.0 $61 — 1. 9 200
ES12N33B 12000/12000 10700/8900 230/208 4.9/5.2 1062/1062 16.0/14.7 3500/2900 11.3/11.3 11.2/11.2 $96 — 3.4 325
ES16N33C 15500/15300 10700/8900 230/208 6.5/7.1 1435/1417 16.0/14.7 3500/2900 10.8/10.8 10.7/10.7 $129 — 3.4 300
EM18N34B 20000/20000 13000/10600 230/208 9.3/10.2 2041/2041 19.5/17.0 5500/4650 10.4/10.4 10.3/10.3 $225 — 7. 0 750
EL24N35B 24000/24000 17300/14300 230/208 10.9/11.6 2308/2308 24.0/22.4 5500/4650 9.4/9.4 9.4/9.4 $225 — 6.0 425
EL36N35B 36000/35500 17300/14300 230/208 17.5/19.2 4000/3944 24.0/22.4 5500/4650 9.0/9.0 9.0/9.0 $360 — 12.0 725
* YS10N10C heat pump operates on 115 volt and IS NOT equipped with supplemental heat . Will not provide heat at temperatures below 40˚F. Friedrich room air conditioners are
designed to operate in outdoor temperatures from 60˚F to 115˚F.
Kühl+ Heat Pump heating information indicates heat pump performance. Kühl+ Electric Heat heating information indicates electric heat strip performance. For Kühl+ Heat Pump
electric heating performance refer to corresponding Kühl+ Electric Heat model.
As an ENERGY STAR
®
partner, Friedrich Air Conditioning Co. has determined that the selected ENERGY STAR
®
models meet the ENERGY STAR
®
guidelines for energy ef c iency.
EER is the unit’s Energy Efciency Ratio; CEER is the unit’s Combined Energy Efciency Ratio.
Your energy costs will depend on your utility rates and use. The estimated energy cost is based on an electricity cost of $.12 per kWh. For more information, visit www.ftc.gov/energy.
Due to continuing research in new energy-saving technology, specications are subject to change without notice.