Brochure (2021)
7
* Minimum extensions when mounted in a window.
** Minimum widths achieved using one side curtain assembly as opposed to both in a standard installation.
NOTE: S, M and L sleeves may be installed in window with no side kits if properly installed.
WINDOW INSTALLATION THRU-WALL INSTALLATION
Sleeve
Height 
Inches
Width
Inches 
Depth 
with Front 
Inches
Shell Depth
to Louvers
 Inches
Minimum
Extension
Into Room* 
Inches
Minimum 
Extension
Outside
* Inches
Window Width 
Inches
Thru-the-wall Installation
Finished Hole Inches
Carton Dimensions
Inches
Minimum** Maximum Height Width
Max. Depth 
  Height Width Depth
Q 14 
1
/
4
" 19 
3
/
4
" 21 
3
/
8
" 8 
1
/
2
" 5 
1
/
2
" 10 
3
/
4
" 22" 42" 14 
1
/
2
" 20" 8 
1
/
2
" 18 
3
/
4
" 22" 25 
1
/
2
"
S 15 
15
/
16
" 25 
15
/
16
" 29" 8 
3
/
4
" 5 
3
/
4
" 16 
15
/
16
" 27 
3
/
8
" 42" 16 
3
/
16
" 26 
3
/
16
" 7 
3
/
8
" 19" 29" 34 
1
/
2
"
M 17 
15
/
16
" 25 
15
/
16
" 29" 8 
3
/
4
" 5 
3
/
4
" 16 
15
/
16
" 27 
3
/
8
" 42" 18 
3
/
16
" 26 
3
/
16
" 7 
3
/
8
" 21" 29" 34 
1
/
2
"
L 20 
3
/
16
" 28" 35 
1
/
2
" 16 
1
/
2
" 5 
3
/
8
" 18 
15
/
16
" 29 
7
/
8
" 42" 20 
3
/
8
" 28 
1
/
4
" 15 
1
/
8
" 24 
1
/
2
" 31 
5
/
8
" 38 
7
/
8
"
FRONT
SIDE VIEW
SLEEVE DIMENSIONS DRAWING
CIRCUIT RATING/ BREAKER/ POWER CORD
Model
Circuit Rating 
Breaker or
T-D Fuse
Plug Face 
(NEMA#)
Power Cord 
Length (ft.)
Wall Outlet 
Appearance
All KCQ MODELS. KEQO8A11A.
KCS08A10A, KCS10A10A, 
KCS12A10A and KCS14A10A. 
KHS10A10A. KCM14A10A.
125V - 15A 5 - 15P 6
KCS12A30A and KCS16A30A. 
KCM18A30A and KCM21A30A.
250V - 15A 6 - 15P 6
KCL24A30B and KCL28A30A. 
KES12A33A and KES16A33A. 
KHS12A33A.
250V - 20A 6 - 20P 6
KCL36A30A. KEM18A34A and 
KEL24A35B and KEL36A35A. 
KHM18A34A and KHL24A35A.
250V - 30A 6 - 30P 6
INSTALLATION
COOLING SIZING GUIDE
AREA TO BE 
CONDITIONED
IN SQ. FT.
APPROXIMATE 
COOLING BTU 
REQUIRED 
100 - 150  5000 
150 - 250  6000 
250 - 300  7000 
300 - 350  8000 
350 - 400  9000 
400 - 450  10000 
450 - 550  12000 
550 - 700  14000 
700 - 1000  18000 
1000 - 1200  21000 
1200 - 1400  23000 
1400 - 1500  24000 
1500 - 2000  30000 
2000 - 2500  34000 
Guide based on normal room in-
sulation, average number of sun 
exposed windows and two person 
occupancy
.
1. If heavily shaded, reduce cooling 
Btus required by 10%
2. If very sunny, increase cooling 
Btus required by 10%
3. Add 500 Btus per person over 2 
people
4. Add 4,000 Btus if the area is a 
kitchen