Specification Guide
7
* Minimum extensions when mounted in a window.
** Minimum widths achieved using one side curtain assembly as opposed to both in a standard installation.
NOTE: S, M and L sleeves may be installed in window with no side kits if properly installed.
Sleeve
Height 
Inches
Width
Inches 
Depth 
with Front 
Inches
Shell Depth
to Louvers
 Inches
Minimum
Extension
Into Room* 
Inches
Minimum 
Extension
Outside
* Inches
Window Width 
INCHES
In-wall Installation
Finished Hole Inches
Carton Dimensions
Inches
Minimum** Maximum Height Width
Max. Depth 
  Height Width Depth
Q 14 
1
/
4
" 19 
3
/
4
" 21 
3
/
8
" 8 
1
/
2
" 5 
1
/
2
" 10 
3
/
4
" 22" 42" 14 
1
/
2
" 20" 8 
1
/
2
" 18 
3
/
4
" 22" 25 
1
/
2
"
S 15 
15
/
16
" 25 
15
/
16
" 29" 8 
3
/
4
" 5 
3
/
4
" 16 
15
/
16
" 27 
3
/
8
" 42" 16 
3
/
16
" 26 
3
/
16
" 7 
3
/
8
" 19" 29" 34 
1
/
2
"
M 17 
15
/
16
" 25 
15
/
16
" 29" 8 
3
/
4
" 5 
3
/
4
" 16 
15
/
16
" 27 
3
/
8
" 42" 18 
3
/
16
" 26 
3
/
16
" 7 
3
/
8
" 21" 29" 34 
1
/
2
"
L 20 
3
/
16
" 28" 35 
1
/
2
" 16 
1
/
2
" 5 
3
/
8
" 18 
15
/
16
" 29 
7
/
8
" 42" 20 
3
/
8
" 28 
1
/
4
" 15 
1
/
8
" 24 
1
/
2
" 31 
5
/
8
" 38 
7
/
8
"
FRONT
SIDE VIEW
SLEEVE DIMENSIONS DRAWING
CIRCUIT RATING/ BREAKER/ POWER CORD
Model
Circuit Rating 
Breaker or
T-D Fuse
Plug Face 
(NEMA#)
Power Cord 
Length (ft.)
Wall Outlet 
Appearance
All KCQ MODELS. KEQO8A11A.
KCS08A10A, KCS10A10A, 
KCS12A10A and KCS14A10A. 
KHS10A10A. KCM14A10A.
125V - 15A 5 - 15P 6
KCS12A30A and KCS16A30A. 
KCM18A30A and KCM21A30A.
250V - 15A 6 - 15P 6
KCL24A30A and KCL28A30A. 
KES12A33A and KES16A33A. 
KHS12A33A.
250V - 20A 6 - 20P 6
KCL36A30A. KEM18A34A and 
KEL24A35A and KEL36A35A. 
KHM18A34A and KHL24A35A.
250V - 30A 6 - 30P 6
INSTALLATION