Service & Parts Manual (2019, 2020, 2021, 2022)
260 PB
TROUBLESHOOTING
E36 / Blank Display
Doescommunicationwiring
meetspecifications?
14gaugestrandedwiringrated
for600v
Replacewiring
asrequired.
Yes
Arethereanyjunctionboxesor
splicesinthewiringexceptfor
coderequireddisconnects?
No
Replacewiring
asrequired.
Yes
IsWiringconnectedtothe
properterminals?
L,N,S1arenotalways
configuredfromlefttoright.
No
Correctwiring
connections.
Yes
CheckLineVoltageatindoor
andOutdoorUnitsfor115or
230VACasrequired.
Isvoltagecorrect?
Traceback
sourceof
problemand
correct.
No
Yes
Isthejiggleswitchoperating
correctly?Openloweraccess
panelanddepressswitchwith
suitabletoolandseeiferror
goesaway.
Yes
Repairor
adjustjiggle
switch.
No
Iscondensatepumpbeing
poweredfromterminalblock?
Itmusthaveit’sownpower
source.
Connect
condensate
pumptoits
ownpower
source.
Yes
Yes
MeasurevoltagebetweenS1
andN.Isthevoltagefluctuating
between0and24vdc?
No
Replaceindoor
oroutdoor
controlboards
asrequired.
No
BlankDisplay/E36Error
Checktheindoorandoutdoor
fanmotors.SeeComponent
Testingsection.Domotors
checkgood?
Replacemotor
asrequired
End
See Figure 702
See Figure 701