SPECIFICATIONS
Product Specications 18K, 24k and 36k Outdoor Condensor
Multi‑Zone Flex 2 Indoor units 2 or 3 indoor units 2 to 4 indoor units 2 to 5 indoor units
Model Name FPHMR18A3A FPHMR24A3A FPHMR36A3A FPHMR42A3A
Rated
current
Cooling 95
ºF
A Rated
Range)
6.5 8.7 11 17.5
Heating 47
ºF
A Rated
Range)
7.3 8.7 13 16
Dimension & Weight
Net Dimension (WxHxD) inch 39x17 3/4x28 3/4 43 3/8x18 1/8x36 1/4 43 3/8x18 1/8x47 1/4
43 3/8x18 1/8x47 1/4
Net Weight lbs 108.0 158.73 188.5 85.5
Package Dimension (WxHxD) inch 39x17 3/4x28 3/4 43-3/8x18-1/8x36-1/4 43-3/8x18-1/8x47-1/4 43 3/8x18 1/8x47 1/4
Gross Weight Ibs 119 169.76 220.5 220.5
Piping Diameter(Liquid) inch 1/4 1/4 1/4 1/4
Diameter(Gas) inch 3/8 3/8 3/8 3/8
Min/Max Length (Each) ft 25/82 25/66 25/66 25/66
Max Length
(Total)
ft 164 197 246 262
Max Height ft 49 49 49 49
Factory Refrigerant Charge oz 63.49 81.13 105.82 120
Additional Refrigerant Charge oz/ft (L‑50 ft * 0.16 oz./ft) (L‑75 ft * 0.16 oz./ft) (L‑98 ft * 0.16 oz./ft) (L‑125 ft * 0.16 oz./ft)
1. Test conditions
Cooling : Indoor: DB80 °C/ WB 67ºF Outdoor: DB95 °C/ WB75°F
Heating: Indoor: DB70 °C/ WB 60ºF Outdoor: DB47 °C/ WB 43 °F
2. The Sound Pressure Level is based on the following conditions:
Outdoor unit:
Measure the noise value of 3 points, the points are 3’(ft) in front of the three sides of the unit surface.
(front/left/right)and height =1/2(unit height +3) ft from oor level, and calculate the weighted average of the noise.
3. The above data was measured in an anechoic chamber. Please take into consideration reected sound of your specic
application environment.