Extended Capacity Charts (2020, 2021)

DuctedFPHMR24A3A‐Heating
TC PI TC PI TC PI TC PI TC PI
kBtu/h kW kBtu/h kW kBtu/h kW kBtu/h kW kBtu/h kW
Indoor
units(Btu)
OutdoorAirTemp. IndoorAirTemp.°FDB
°FDB °FWB
60 65 70 75 78
41 37 37.59 3.81 36.62 3.89 35.87 3.95 34.88 4.04 34.00 4.12
47 43 40.51 3.62 39.47 3.64 38.77 3.72 37.65 3.79 36.61 3.87
50 47 36.82 3.25 35.88 3.27 35.24 3.35 34.23 3.41 33.28 3.48
59 50 33.06 2.88 32.21 2.90 31.64 2.97 30.73 3.04 29.88 3.08
68 59 29.21 2.51 28.46 2.54 27.96 2.59 27.15 2.65 26.41 2.70
75 65 21.07 1.78 20.53 1.80 20.17 1.85 19.59 1.89 19.05 1.92
12+12+12
98