Submittal
Specifications
* Operates on 115 volt and is not equipped with supplemental heat. Will not provide heat at temperatures below 40°F.
Friedrich room air conditioners are designed to operate in outdoor temperatures from 60°
F to 115°
F.
Kühl+ Heat Pump heating information indicates heat pump performance. Kühl+ and Chill+ Electric Heat heating information indicates electric heat strip performance. For
Kühl+ Heat Pump electric heating performance refer to corresponding Kühl+ Electric Heat model.
As an ENERGY STAR
®
partner, Friedrich Air Conditioning Co. has determined that the selected ENERGY STAR
®
models meet the ENERGY STAR
®
guidelines for energy
efciency.
The consumer- through the AHAM Room Air Conditioner Certication Program- can be certain that the AHAM Certication Seal accurately states the unit’s cooling and
heating capacity rating, the amperes and the energy efciency ratio.
Your operating costs will depend on your utility rates and use. The estimated operating cost is based on a electricity cost of $ .12 per kWh. For more information, visit www.
ftc.gov/energy.Due to continuing research in new energy-saving technology, specications are subject to change without notice.
LISTED
ROOM AIR CONDITIONERS
183H
Model Cooling Btu Heating Btu
Volts
Rated
Cooling
Amps
Cooling
Watts
Heating
Amps
Heating
Watts
Energy
Efciency
Ratio EER
Estimated
Yearly
Operating
Cost COP
Moisture
Removal-
Pints/HR CFM Sleeve
Net
Wt.
lbs.
Ship
Wt.
lbs.
Kühl
®
SQ05N10B 5200 - 115 4.7 464 - - 11.2 $42 - 0.5 190 Q 72 85
SQ06N10B 5700 - 115 4.7 509 - - 11.2 $46 - 0.5 190 Q 72 85
SQ08N10B 7900 - 115 6.4 705 - - 11.2 $63 - 1.2 200 Q 71 84
SQ10N10 9600 - 115 9.2 980 - - 9.8 $88 - 2.1 240 Q 71 84
SS08N10B 8000 - 115 6.1 696 - - 11.5 $63 - 1.9 255 S 99 121
SS10N10B 9700 - 115 7.8 858 - - 11.3 $77 - 2.5 300 S 106 128
SS12N10B 12000 - 115 9.7 1062 - - 11.3 $96 - 3.0 300 S 112 134
SS14N10A 13500 - 115 12.0 1250 - - 10.8 $113 - 4.0 275 S 116 133
SS12N30B 12000/12000 - 230/208 4.9/5.2 1062/1062 - - 11.3/11.3 $96 - 3.4 325 S 112 134
SS16N30 15500/15200 - 230/208 6.5/7.1 1449/1421 - - 10.7/10.7 $130 - 4.8 350 S 116 136
SM15N10B 15000 - 115 12.0 1339 - - 11.2 $121 - 3.5 360 M 141 154
SM18N30 17500/17200 - 230/208 7.4/8.0 1635/1607 - - 10.7/10.7 $147 - 4.6 350 M 140 161
SM21N30B 20500/20000 - 230/208 9.3/10.2 2092/2062 - - 9.8/9.7 $188 - 6.0 425 M 132 153
SM24N30A 23500/23200 - 230/208 12.7/13.6 2765/2730 - - 8.5/8.5 $249 - 7.1 430 M 152 173
SL24N30B 24000/23800 - 230/208 10.8/11.4 2449/2429 - - 9.8/9.8 $220 - 7.0 640 L 191 212
SL28N30B 28000/27600 - 230/208 13.0/14.0 2857/2875 - - 9.8/9.6 $257 - 8.5 640 L 193 214
SL36N30B 36000/35500 - 230/208 17.5/19.2 4000/3944 - - 9.0/9.0 $360 - 12.0 725 L 212 248
Kühl+
®
(Heat Pump)
YS10N10B* 9500 8000 115 8.2 913 7.3 870 10.4 $82 2.7 2.0 300 S 109 131
YS12N33B 11500/11300 9400/9000 230/208 5.0/5.4 1106/1087 4.6/5.0 1132/1139 10.4/10.4 $100 2.4/2.3 3.0 375 S 115 136
YM18N34B 17500/17200 15500/15000 230/208 7.5/8.1 1683/1654 7.8/8.4 1824/1765 10.4/10.4 $151 2.5/2.5 5.4 370 M 141 154
YL24N35B 24000/24000 22000/22000 230/208 10.8/11.6 2449/2449 10.7/11.4 2391/2391 9.8/9.8 $220 2.6/2.6 7.0 600 L 197 211
Kühl+
®
(Electric Heat)
EQ08N11B 7900 4000 115 6.4 705
11.2 1290 11.2 $61 - 1.2 200 Q 72 84
ES12N33B 12000/12000 10700/8900 230/208 4.9/5.2 1062/1062 16.0/14.7 3500/2900 11.3/11.3 $96 - 3.4 325 S 113 128
ES16N33 15500/15200 10700/8900 230/208 6.5/7.1 1449/1421 16.0/14.7 3500/2900 10.7/10.7 $130 - 4.8 350 S 117 133
EM18N34 17500/17200 13000/10600 230/208 7.4/8.0 1635/1607 19.5/17.0 4200/3500 10.7/10.7 $147 - 4.6 350 M 141 154
EM24N34A 23500/23200 13000/10600 230/208 12.7/13.6 2765/2730 19.5/17.0 4200/3500 8.5/8.5 $249 - 7.1 430 M 153 166
EL36N35B 36000/35500 17300/14300 230/208 17.5/19.2 4000/3944 24.0/22.4 5500/4650 9.0/9.0 $360 - 12.0 725 L 213 246
ENERGY STAR
®
models