Operating Guide Compact Programmable Room Air Conditioner with remote control CP18C30 Please register your air conditioner Whenever you call to request service on your appliance, you will need to provide your complete model number and serial number. You can find this information on the model and serial number label.
Table of Contents Air Conditioner Safety ......................................................................................................................................................2 Installation Requirements ...............................................................................................................................................3 Tools and Parts ....................................................................................................................................
IMPORTANT SAFETY INSTRUCTIONS WARNING: To reduce the risk of fire, electrical shock or injury when using your air conditioner, follow these basic precautions: Plug into a grounded 3 prong outlet. Do not use an extension cord. Do not remove ground prong. Unplug air conditioner before servicing. Do not use an adapter. Use two or more people to move and install air conditioner.
Window installation Electrical Requirements Window opening measurements: 30"min. to 40" max. (76.2 cm to 101.6 cm) opening width. WARNING 20" min. (50.8 cm) opening height. Electrical Shock Hazard Plug into a grounded 3 prong outlet. Do not remove ground prong. A Do not use an adapter. B Do not use an extension cord. Failure to follow these instructions can result in death, fire, or electrical shock. A. 30" min. (76.2 cm) B . 20" min. (50.
WARNING Recommended grounding method This air conditioner must be grounded. This air conditioner is equipped with a power supply cord having a grounded 3 prong plug. To minimize possible shock hazard, the cord must be plugged into a mating, grounded 3 prong outlet, grounded in accordance with all local codes and ordinances. If a mating outlet is not available, it is the customer' s responsibility to have a properly grounded 3 prong outlet installed by a qualified electrical installer.
Installation Instructions Unpacking WARNING 3. Remove the window lock bracket and screw from the air conditioner and set aside. Excessive Weight Hazard Use two or more people to move and install air conditioner. Failure to do so can result in back or other injury. Remove packaging materials � Remove and dispose of/recycle packaging materials. Remove tape and glue residue from surfaces before turning on the air conditioner. Rub a small amount of liquid dish soap over the adhesive with your fingers.
Window Installation (on some models) NOTES: � Handle air conditioner gently. Bottom view � Be sure your air conditioner cabinet does not fall out of the opening during installation or removal. � The place where the power cord exits the air conditioner should be no more than 4 ft (122 cm) from a grounded 3 prong outlet. � Do not block the louvers on the front panel. � Do not block the louvers on the outside of the air conditioner.
Install Cabinet into Window Attach Side Curtains to Window Frame � Handle air conditioner gently. � Be sure your air conditioner cabinet does not fall out of the opening during installation or removal. � The place where the power cord exits the air conditioner should be no more than 4 ft (122 cm) from a grounded 3 prong outlet. � Do not block the louvers on the front panel. � Do not block the louvers on the outside of the air conditioner. 1. Center empty cabinet in window.
2. Using #10 x ⁷⁄₈" pan-head Phillips screws, attach bracket to cabinet. Repeat for other bracket. 3. Turn the adjustment bolt for each bracket until the bolt touches the wall. 4. Turn the locking nut on adjustment bolt to lock in position. Complete Installation 1. Insert seal behind the top of the lower window sash and against the glass of the upper window. 2. Place one window-lock bracket on top of lower window and against upper window sash on each side of window. 3.
� Use 1" (2.5 cm) or thicker lumber for wood frame. A 2. Insert cabinet into the framed wall opening. The top of the cabinet should extend ³⁄₄" (19.1 mm) into the room. If there is trim, the cabinet should extend ³⁄₄" (19.1 mm) past the trim. B A B C A. Outside width B. Outside height C. Depth 4. Apply wood preservative to the outside exposed surface. 5. Insert the frame in the wall opening. Square and level frame. 6. Attach frame securely to the wall. A. ³⁄₄ " (19.1 mm) extending into room B.
WARNING 5. Using 2 - #10 x ³⁄₈" round-head screws, attach bottom front of panel. Electrical Shock Hazard Connect green ground wire to ground screw. Failure to do so can result in death or electrical shock. 3. Connect green ground wire to cabinet base with ground screw. Position ground wire pointing straight up. Put excess ground wire between coil and air conditioner cabinet. NOTE: For through-the-wall installations, if needed, install molding around room side of cabinet. A WARNING B A.
Starting Your Air Conditioner—Digital Control Temperature Money Saver® Auto Swing Press, or press and hold, the plus button to raise the temperature 1º until it reaches 86ºF (30ºC). Timer F 0 F 0 Temp/Hour Temp/Hour Hr. POWER Hr. High Cool Mode Med Fan Speed Low Fan Only � 1. Press POWER to turn on air conditioner. Timer Delay To set the Timer for a 1- to 24-hour delay until the air conditioner turns off (the air conditioner must be On): POWER 1. Press TIMER.
To operate air conditioner with remote control NOTE: Remote control may vary in appearance. To raise the temperature: Press the plus button to raise the temperature. Each time you press or hold the plus button, the temperature will go up 1º until it reaches 86°F (30°C). To lower the temperature: Press the minus button to lower the temperature. Each time you press or hold the minus button, the temperature will go down 1º until it reaches 64°F (18°C).
Air Conditioner Care Your new air conditioner is designed to give you many years of dependable service. This section tells you how to clean and care for your air conditioner properly. Call your local authorized dealer for an annual checkup. Remember… the cost of this service call is your responsibility. Cleaning the Air Filter The air filter is removable for easy cleaning. A clean filter helps remove dust, lint, and other particles from the air and is important for best cooling and operating efficiency.
Air conditioner power supply cord trips (Reset button pops out) � Disturbances in your electrical current can trip (Reset button will pop out) the power supply cord. Press and release RESET (listen for click; Reset button will latch and remain in) to resume operation. � Electrical overloading, overheating, cord pinching or aging can trip (Reset button will pop out) the power supply cord.
Friedrich Air Conditioning Company P.O. Box 1540 San Antonio, TX 78295 210.357.4400 www.friedrich.com ROOM AIR CONDITIONERS LIMITED WARRANTY FIRST YEAR ANY PART: If any part supplied by FRIEDRICH fails because of a defect in workmanship or material within twelve months from date of original purchase, FRIEDRICH will repair the product at no charge, provided room air conditioner is reasonably accessible for service.