Service and Parts Manual (2019, 2020, 2021, 2022)
Table Of Contents
- _GoBack
- INTRODUCTION
- SPECIFICATIONS
- OPERATION
- R-410A SEALED SYSTEM REPAIR
- COMPONENT TESTING
- TROUBLESHOOTING
- WIRING DIAGRAMS
- PARTS CATALOG
- PARTS CATALOG
- Chill Premier Models: CCW06B10A CCW08B10A CCW10B10A CCW12B10A
- Chill Premier Models: CCW15B10A CCW18B30A
- Chill Premier Models: CCW24B30A
- Chill Premier Models: CEW08B11A, CEW12B33A
- Chill Premier Models: CEW18B33A
- Chill Premier Models: CEW24B33A
- Chill Premier Models: CCF05A10A CCF06A10A CCF08A10A
- Chill Premier Models: CCF10A10A CCF12A10A
- Unifit Models: UCT08A10A UCT10A10A UCT12A10A UCT10A30A
- Unifit Models: UCT12A30A, UCT14A30A
- Unifit Models: UCT10A30B
- Unifit Models: UCT14A30B
- Unifit Models: UET08A11A UET10A33A UET12A33A
- Unifit Models: UET14A33A
- Available Accessories
40 PB
TROUBLESHOOTING
Compressor Or Outdoor Fan Does Not Operate At All
Figure 716
Compressor or outdoor fan does not operate at all.
Re-input after power of f
Set the desired temperature of remote controller to be lower by 2°C or
over than room temperature, and start the cooling operation.
Does not operate at all.
Repeat running/stopping
at a short time period.
Temperature sensor
open/short check
Thermistor and evaporator
surface contact check.-
Clearance is needed (5mm).
Connector check
(Contact & power)
Connector check
(Contact & power)
Disconnection/short
circuit check of
connecting wire
OLP/High pressure
switch/Low pressure
switch check
Electric wire connection
check for outdoor side
Operation mode
(dehumidifying) check
Compressor & motor
detail check
PCB assy check
Check:
Temperature sensing circuit
Relay output
Insulation resistance
Coil resistance
Capacitor capacity
Compressor OLP