Installation and Operations Manual (2019, 2020, 2021)
Table Of Contents
4
OFFSET
STOOL
SILL
INTERIOR
WALL
EXTERIOR
WALL
Air conditioner
Bottom channel
23” to 36”
660mm to 914mm
16”
406mm
1. This air conditioner is designed to be installed
 In a standard double-hung window with a window
 width between 23” and 36” (660mm-914mm).
2. The air conditioner can be installed without the
 accordion panels fit in a narrow window opening.
3. The lower sash ( the lower part of the window that
 moves up and down) must allow for 16” of vertical
 clearance when open. 
4. All supporting parts must be secured to firm wood,
 masonry, or metal.
5. The electrical outlet must be within reach of the 
 power cord.
Window preparation
ALL INFORMATION AND THE TECHNICAL SPECIFICATIONS PRESENTED IN THIS USER’ S MANUAL ARE THE PRESENTATION 
OF THE MANUFACTURE. PLEASE READ AND FOLLOW THESE INSTRUCTIONS CAREFULLY.
How to Install
NOTE:This is necessary for proper condensed water 
utilization and drainage. If you are not using the Side 
Panels for any reason, this pitch to the rear muse be 
maintained!
Remove the air conditioner from the box and place on a 
hard flat surface, as floor, a bench or a table. There is a 
Left and Right Window Filler Panel - be sure to use the 
proper panel for each side. When installed the flange for 
securing the panel in place to the window sill will be facing 
into the room.