Service & Parts Manual
Table Of Contents
- _GoBack
- INTRODUCTION
- SPECIFICATIONS
- OPERATION
- R-410A SEALED SYSTEM REPAIR
- COMPONENT TESTING
- Hermetic Components Check
- Reversing valve description and operation
- Testing The Reversing Valve Solenoid Coil
- Checking The Reversing Valve
- Replace The Reversing Valve
- Touch Test Chart : To Service Reversing Valves
- Compressor Checks
- Compressor Replacement
- Compressor Replacement -Special Procedure in Case of Compressor Burnout
- Fan Motor
- Capacitors
- TROUBLESHOOTING
- WIRING DIAGRAMS
- PARTS CATALOG
- Unifit Models: UET14A33A
- Unifit Models: UET08A11A UET10A33A UET12A33A
- Unifit Models: UCT12A30, UCT14A30A
- Unifit Models: UCT08A10A UCT10A10A UCT12A10A UCT10A30A
- Chill Premier Models: CCF10A10A CCF12A10A
- Chill Premier Models: CCF05A10A CCF06A10A CCF08A10A
- Chill Premier Models: CEW24B33A
- Chill Premier Models: CEW18B33A
- Chill Premier Models: CEW08B11A, CEW12B33A
- Chill Premier Models: CEW08B11A, CEW12B33A
- Chill Premier Models: CEW08B11A, CEW12B33A
- Chill Premier Models: CCW24B30A
- Chill Premier Models: CCW24B30A
- Chill Premier Models: CCW15B10A CCW18B30A
- Chill Premier Models: CCW06B10A CCW08B10A CCW10B10A CCW12B10A
- Available Accessories
29 PB
COMPONENT TESTING
Reversing valve description and operation
The Reversing Valve controls the direction of refrigerant ow to the indoor and outdoor coils. It consists of a
pressure-operated, main valve and a pilot valve actuated by a solenoid plunger. The solenoid is energized during
the heating cycle only. The reversing valves used in the RAC system is a 2-position, 4-way valve.
The single tube on one side of the main valve body is the high-pressure inlet to the valve from the compressor.
The center tube on the opposite side is connected to the low pressure (suction) side of the system. The other two
are connected to the indoor and outdoor coils. Small capillary tubes connect each end of the main valve cylinder
to the “A” and “B” ports of the pilot valve. A third capillary is a common return line from these ports to the suction
tube on the main valve body. Four-way reversing valves also have a capillary tube from the compressor discharge
tube to the pilot valve.
The piston assembly in the main valve can only be shifted by the pressure differential between the high and low
sides of the system. The pilot section of the valve opens and closes ports for the small capillary tubes to the main
valve to cause it to shift.
A
B
Figure 702 (Reversing Valve)