Manual
4
Forproperunitperformance and maximum operating liferefer to the minimum installation clearances
below.
Figure 2
Figure 1
12"
24"60"
KAPVKAPVKAPV
POLE
FENCE
MAJOR OBSTRUCTION
BUILDING
OUTDOOR
CONDENSING
UNIT
72"
24"
SHRUB
A
B
60"60"
60"
60"
LARGER RECESS OK. IF A> 5xB
12"
6"
60"
60"
60"
6"
60"
60"
6"
60" 60"
SMALL RECESS OK
VERT-I-PAK
®
units must be installed on an outside wall. Confined spaces and/or covered areas should be
avoided. Units should be installed no closer than 12" apart when two units are side by side. If three or more
units are to operate next to one another allow a minimum of 60" between units or pairs of units. Also, a vertical
clearance of 60" should be maintained between units. Units installed on the bottom floor should be mounted at
least 6" off of the ground.
Any time obstructions are present use the
following guidelines for proper spacing
from the VERT-I-PAK louver:
For minor obstructions such as lamp
poles or small shrubbery a clearance
of 24” from the outdoor louver should
be maintained.
For major obstructions such as a solid
fence, wall or other heat reject
ing
device like a condensing unit, a
minimum distance of 72” should be
kept.
•
•
®
The above suggestions are for reference only and do not represent all posible installations. Please contact Friedrich for informa-
tion regarding affects of other installation arrangements.
By following these simple recommendations you can be confident that your Friedrich Vert-I-Pak will provide years of worry-free
operation.