s Installation /Installed View
Figure 16
The V
ert-I-Pak chassis must be inserted into the wall plenum so that the plenum divider gasket makes contact with the condenser
baffle in the unit.The chassis will fit approximately 2 3/8” into the wall plenum.
NOTE: Prior to installing the chassis, ensure that the drain pan and line are free from debris.
C. Place the chassis into the closet with the outdoor side
facing the wall plenum opening.
D. Slide the chassis into the wall plenum until the plenum
divider seal is established and the factory-installed
chassis to plenum gasket has sealed to the top flange of
the plenum. (See Figure 16)
Chassis Installation
NOTE: Prior to installing the chassis, ensure that the drain
pan and line are free from debris.
A. Ensure that the wall plenum is installed in accordance
with the VPAWP1-8/1-14 Installation Manual.
B. Ensure that the VPDP1 drain pan is installed correctly
(see Figure 16). Using the 3/4" plugs supplied with the
pan, plug the unused condensate drain hole. Connect a
drain to the condensate exit location. Be sure to use
teflon tape or approved pipe sealant on all drain
connections and plugs (see Figure 16).
ESP (") Low High
.00" 690 740
.10" 610 700
.20" 560 640
.30" 510 580
.40" 450 520
Model
VEA24/VHA24
Highlighted values indicate
rated performance point.
Excessive Weight Hazard
CAUTION
Use two or more people when
installing your air conditioner.
Failure to do so can result in back
or other injury.
Cut/Sever Hazard
CAUTION
Some edges may be sharp, use
gloves or other hand protection
when handling unit.
Failure to do so can result in minor
to moderate personal injury.
For single speed thermos-
tats connect to the GL
terminal for Low speed or
GH terminal for High
speed. Two speed control
thermostats will use both.