Install Instructions

TUVL -315
K
Optional 2nd Remote UV Light
Installation Instructions
The optional Fresh-Aire Remote UV Light
works with the APCO-X system for enhanced
disinfection, reduced system maintenance,
and improved indoor air quality.
IMPORTANT!
APCO-X Dual lamps are wired in series - connect both for lamps to light
Only qualified technicians should install this product
Install in accordance with relevant building codes
Read instructions carefully including safety warnings
Mounting Options
Installation Notes
Before installing the Fresh-Aire Remote UV Light it is
necessary to determine the optimal mounting location
inside the air system. First, look for the area with the
heaviest mold growth. Also consider a location that will
allow the germicidal UV light to shine on the greatest
surface area.
Some typical mounting locations:
a
Across top of coils
b
Coil “A plate
c
Return-side duct
a
b
c
Important: some materials inside the air system (including
lter media, ex duct, wiring etc.) may not be UV light resistant.
Use the optional UV shield (part #TUV-SHIELD-LPC) or cover
the materials with reective tape.
1
Air Handler Interior Surface Installation
1. Determine the optimal position
for placement of the UV lamp.
2. Use a utility knife to cut a slit in the insulation
on the interior surface.
3. Place the magnetic “Z” bracket
L
directly on
the metal surface or remove the magnet and
hard-mount the bracket using the self-tapping
screws
H
provided. Use foil tape to close the
cut in the insulation.
4. Use plastic quick-nuts to attach the
UV lamp to the “Z” bracket as shown.
2.
3.
4.
2
Coil A plate or Duct Installation
1. Snap the “Z” bracket
L
apart by
bending.
2. Drill a 1” hole in the "A"-plate or duct
then attach the smaller piece of the
bracket with self-tapping screws
H
.
3. Insert the UV lamp into the hole then
use the plastic quick-nuts to attach the
UV lamp to the “Z” bracket as shown.
1.
2.
3.
3
Remote UV Light Conguration
IMPORTANT! Only the APCO-X Dual model has the
electrical capacity and attached cable for the optional
Remote UV Light.
Find the lamp cable on the right underside of the
APCO-X Dual Power Unit.
Drill a 1” hole in the air system
housing then pass the lamp
cable through the hole then
seal the hole with the rubber
grommet to minimize air
leakage.
To add a second UV light to an existing
APCO-X system that is not a Dual model
install a separate Fresh-Aire UV
AHU Series 1 or Blue-Tube UV system.
4
Sight Glass Installation
1. Find a suitable location on the outside
of the duct-work near the UV Lamp
installation and apply the Fresh-Aire UV®
warning/lamp replacement sticker
M
.
2. Drill a ½” hole through the circle on the
sticker. Press the sight glass
N
into hole.
3. Turn on the power and use the sight glass
to conrm that the UV Lamp is operating.
1.
5
Lamp Replacement
The second germicidal UV lamp
K
included with APCO-X Dual models should be replaced
every three years along with the primary lamp.
Note: The UV lamps may continue to emit visible after three years, however, germicidal
eectiveness falls o over time and will quickly drop to near zero after three years.
CAUTION!
UV lamps contain small amounts of mercury - dispose of lamps in accordance with
local environmental regulations. For more information visit www.lamprecycle.org
Note: Use of replacement UV lamps other than Fresh-Aire UV® voids warranty.
WARNING
PROTECT EYES FROM UV LIGHT
TURN OFF UNIT OR DISCONNECT
BEFORE SERVICING
Align Pins with Alignment Key
Push Firmly Together
UV Lamp
Lamp Cable
N
H
L