Fault Code Guide

3. At the PLC filter, connect one lead of the DMM
to the green wire (at the 2-pin connector with the
green and yellow wires) and the other lead to
one of the blue wires (at the 2-pin connector with
the two blue wires). Measure the capacitance.
If the reading is 4.8 to 7.2 µF, go to the
next step.
If the reading is less than 4.8 or more than
7.2 µF, one or more of the internal capaci-
tors is faulty. This may affect PLC function-
ality and/or noise in the electrical system.
Replace the PLC filter.
4. At the PLC filter, connect one lead of the DMM
to one of the blue wires (at the 2-pin connector
that has the two blue wires) and connect the
other lead to the ground where the white wire
terminates. Measure the capacitance.
If the reading is 9.91 to 11.91 µF, the PLC
filter is functioning properly.
If the reading is less than 9.91 or more
than 11.91 µF, check and clean the ground
connection where the white wire termi-
nates and retest. If the reading is still un-
satisfactory, one or more of the internal
capacitors is faulty. This may affect PLC
functionality and/or noise in the electrical
system. Replace the PLC filter.
Meritor WABCO Pneumatic Antilock Braking System
(ABS)
42.00
ABS System Troubleshooting
Business Class M2 Workshop Manual, Supplement 2, June 2002300/18