User Manual
Table Of Contents
ZumLink Z9-C or Z9-T: User Manual
2. ZumLink Z9-C or Z9-T CLI Configuration
Important!: A Serial Port on the computer is required for this procedure.
1. Using the Data Interface Connector (see ZumLink Z9-C or Z9-T Data Interface
Connector (on page 16) for location):
a. Apply power to the ZumLink.
b. Connect to the Serial Interface of the ZumLink.
l The Z9-C model has an RS232 interface and can be connected directly to an
RS232 device.
l FreeWave offers a cable (ASC2414DJ) from the radio to a DB9 connector that
includes a reset button and power input jack.
l The Z9-T model has a TTL interface and does NOT work directly with RS232.
l If connecting up to a device or circuit that is RS232, a circuit is required to adapt
between the two interfaces.
2. If the ZumLink is connected to a computer, open a terminal program (e.g., Tera Term).
Note: In this example procedure, Tera Term is used.
3. In Tera Term, on the File menu, select New Connection.
LUM0075AA Rev May-2016 Page 9 of 40
This document is the property of FreeWave Technologies, Inc. and contains proprietary information owned by
FreeWave. This document cannot be reproduced in whole or in part by any means without written permission from
FreeWave Technologies, Inc.