5. ZumLink Z9-C or Z9-T Settings and Descriptions
Page 19 of 40 LUM0075AA Rev May-2016
This document is the property of FreeWave Technologies, Inc. and contains proprietary information owned by FreeWave. This document cannot be reproduced
in whole or in part by any means without written permission from FreeWave Technologies, Inc.
Note: If the "=" sign is appended to the parameter, it is an implied change to that parameter.
If a value is NOT included after the "=", the value becomes a null, space, or 0 (zero) depending on the parameter.
Example: Entering txPower returns the current value of txPower.
Entering txPower= is an implied change to txPower.
If a value is NOTincluded, it changes txPower to 10.
config
config - ZumLink Settings and Descriptions
Page CLI Command Description
[Page=config] config.factoryDefaults= This setting restores the ZumLink to its factory default configuration.
Example: config.factoryDefaults=set
[Page=config] config.reset= All options reset the ZumLink Z9-C or Z9-T.
The options are:
l config.reset=now
l config.reset=reboot is this valid? John to verify
l config.reset=reset is this valid? John to verify
[Page=config] config.restore= This setting reloads the config settings of the ZumLink that were saved.
Phil asks: What are the options?
Note: Restore happens automatically when the ZumLink starts.
[Page=config] config.save= This setting saves changes made to the ZumLink configuration.
Phil asks: Is NOW the only option? I think one option is config.save=1.
Example: config.save=now