Reference Manual
Table Of Contents
- Preface
- 1. Overview
- Untitled
- 2. Equipment
- 3. Installation
- 4. Basic Radio Programming and Setup
- 4.1. Define the Network Type and the Radio's Role in that Network
- 4.2. Establish Communication with Instrumentation and Computers
- 4.3. Establishing Communication with Other Radios in the Network
- 4.4. Set the Data Transmission Characteristics
- 4.5. Set Radio Passwords
- 4.6. Set the Hop Table Size in the Terminal Interface
- 4.7. Set the Radio to a Single Channel in a Terminal Emulator
- 4.8. Set the Radio to Hop Channels
- 4.9. Edit Frequencies for Multiple Channels
- 5. Configure Point-to-MultiPoint Networks
- 5.1. Point to MultiPoint Network Characteristics
- 5.2. Point-to-MultiPoint Network Quick Start (Terminal Interface)
- 5.3. Overlapping MultiPoint Networks
- 5.4. Establishing Communication with Other Radios in a MultiPoint Network
- 5.5. Routing Communication Through the Network
- 5.6. Setting Other MultiPoint Parameters
- 5.7. Reading Diagnostics in Tool Suite
- 6. Configure Point-to-Point Networks
- 7. View Radio Statistics
- 8. Release Notes
- 9. Additional Radio Information
- Appendix A: Technical Specifications
- Appendix B: RF Board Pin-Out
- Appendix C: RS232 Pin Assignments - DB9
- Appendix D: LRS455 Frequency Table
- Appendix E: Factory Default Settings
- Appendix F: Point-to-MultiPoint Operation LEDs
- Appendix G: Point-to-Point Operation LEDs
- Appendix H: FreeWave Legal Information
- Blank Page
- Blank Page
6. Configure Point-to-Point Networks
LUM0020CD Rev June-2020 Page 80 of 112 Copyright © 2019FreeWave
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
6.3.1. Set the Call Book in Tool Suite
1. In the Tool Suite Configuration application, select the device to program.
2. Click the (2) Call Book tab.
3. In the Number column in Row 0, enter the seven-digit serial number of the radio being
called.
4. In the Repeater 1 column, enter the first Repeater's seven-digit number.
If no Repeaters are being used, leave the column empty.
5. In the Repeater 2 column, enter the second Repeater’s 7-digit number.
If only one Repeater is being used, leave the column empty.
6. If Repeaters are used, select the appropriate Entry to Call option in the MasterCall
Book.
7. To apply the changes, click either the Quick or All icon.
Tool Suite applies the changes to the radio.
6.3.2. Set the Call Book in the Terminal Interface
1. On the Setup menu, click C (2) Edit all Book.
The Modem Call Book window opens.
Figure 11: Modem Call Book window
2. Enter the number or letter associated with the option to select.
3. In the Enter New Number prompt, enter the seven-digit serial number of the radio being
called.
The system prompts for the first Repeater's serial number.
LRS455A-C, LRS455A-CE, LRS455-T
User-Reference Manual
;, FreeWave User Manual - Hyper Terminal GJ[g]L8:J
E.ile ~dit tiew s;all Ir ansfer t:!elp
MODEM CALL BOOK ~ I
Entry to Call
IS
(ALL)
Entry
Number
Repeaterl Repeater2
(0)
960-0405
(1)
912-2890 911-4419
(2)
000-0000
(3)
000-0000
(4)
000-0000
(5)
000-0000
(6)
000-0000
(7)
000-0000
(8)
000-0000
(9)
000-0000
(C)
Change Entry to Use (0-9) or A(ALL)
(Esc)
Exit to Main Menu
Enter
all zeros (000-0000) as your last number
1n list
J
v i
< I
>
Connected 1 :38 :52 Auto dete ct
19200 8-N-1
SCROLL CAPS
NUM
Capture Print echo
...