Reference Manual

Table Of Contents
6. Configure Point-to-Point Networks
LUM0020CD Rev June-2020 Page 78 of 112 Copyright © 2019FreeWave
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
14. Enter the Slave serial number in the Master’s Call Book.
15. Enter the Master’s Serial number in the Slave’s Call Book or
disable the Slave Security (on page 47) parameter in the Slave.
Note: For more information about setting up the Call Book see Using in Point-to-Point
Networks.
16. On the Main Menu, type 3 and press <Enter>.
17. Set these parameters so they are identical on all radios in the network:
a. Max Packet Size and Min Packet Size (on page 40)
b. RF Data Rate (on page 45)
c. Rx Frequency (on page 46)
d. Tx Frequency (on page 50)
Note: The Tx Frequency and Rx Frequency options, or Frequency Key, are located in the F
submenu after you press 0 to access the Frequency Key menu in Main menu 3.
FREEWAVE Recommends: Changing these settings from the factory defaults may help to
eliminate interference from other FreeWave networks.
18. Press <Esc> to return to the Main menu.
Shortly after both radios are plugged in they should establish a link with each other and the
connection is complete.
19. Using the Point-to-Point Operation LEDs (on page 107), verify that the radios are operating
as expected.
20. Press <Esc> to exit the Setup menu and resume normal radio operation.
LRS455A-C, LRS455A-CE, LRS455-T
User-Reference Manual
I
I I