6. Configure Point-to-Point Networks
LUM0020CD Rev June-2020 Page 76 of 112 Copyright © 2019FreeWave
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
Note: Changing these settings from the factory defaults may help to eliminate interference
from other FreeWave networks.
14. Click the Call Book tab.
15. Enter the Slave serial number in the Master’s Call Book.
16. Enter the Master’s Serial number in the Slave’s Call Book, or disable the Slave Security
parameter in the Slave.
Note: For more information about setting up the Call Book see Using Call Book in Point-to-
Point Networks (on page 79).
Shortly after both radios are plugged in they should establish a link with each other and the
connection is complete.
17. Using the Point-to-Point Operation LEDs (on page 107), verify that the radios are operating
as expected.
18. On the Configuration application in the Network Title ribbon:
l Click All to send all the settings for all parameters.
l Click Quick to send only the changed parameters.
Note: Quick is only available if Read Radio is selected and parameter settings are
NOT sent from a template to the radio.
LRS455A-C, LRS455A-CE, LRS455-T
User-Reference Manual