Reference Manual
Table Of Contents
- Preface
- 1. Overview
- Untitled
- 2. Equipment
- 3. Installation
- 4. Basic Radio Programming and Setup
- 4.1. Define the Network Type and the Radio's Role in that Network
- 4.2. Establish Communication with Instrumentation and Computers
- 4.3. Establishing Communication with Other Radios in the Network
- 4.4. Set the Data Transmission Characteristics
- 4.5. Set Radio Passwords
- 4.6. Set the Hop Table Size in the Terminal Interface
- 4.7. Set the Radio to a Single Channel in a Terminal Emulator
- 4.8. Set the Radio to Hop Channels
- 4.9. Edit Frequencies for Multiple Channels
- 5. Configure Point-to-MultiPoint Networks
- 5.1. Point to MultiPoint Network Characteristics
- 5.2. Point-to-MultiPoint Network Quick Start (Terminal Interface)
- 5.3. Overlapping MultiPoint Networks
- 5.4. Establishing Communication with Other Radios in a MultiPoint Network
- 5.5. Routing Communication Through the Network
- 5.6. Setting Other MultiPoint Parameters
- 5.7. Reading Diagnostics in Tool Suite
- 6. Configure Point-to-Point Networks
- 7. View Radio Statistics
- 8. Release Notes
- 9. Additional Radio Information
- Appendix A: Technical Specifications
- Appendix B: RF Board Pin-Out
- Appendix C: RS232 Pin Assignments - DB9
- Appendix D: LRS455 Frequency Table
- Appendix E: Factory Default Settings
- Appendix F: Point-to-MultiPoint Operation LEDs
- Appendix G: Point-to-Point Operation LEDs
- Appendix H: FreeWave Legal Information
- Blank Page
- Blank Page
5. Configure Point-to-MultiPoint Networks
LUM0020CD Rev June-2020 Page 72 of 112 Copyright © 2019FreeWave
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
5.7. Reading Diagnostics in Tool Suite
The Network Diagnostics application provides a place to view diagnostic data for all the devices
connected to the Master in the network in real time.
Important!: The Network Diagnostics application is NOT meant to replicate the functionality of a
Network Management System.
It is a tool intended for occasional network monitoring or troubleshooting in the field, not for
continuous, long-term collection of diagnostic data.
This topic provides basic steps for reading diagnostics using Tool Suite. Tool Suite stores the
diagnostic data in the database for import from or export to a diagnostic file.
Note: For information about the available data, recommended best practices, and importing and
exporting files using the Network Diagnostics application, see the Tool Suite User Manual.
To help identify the radios in the network when running Network Diagnostics, set the Radio
Name and Radio ID settings on the MultiPoint Parameters tab.
Important!: Network Diagnostics must be run from the Master radio.
Diagnostics require:
l A setting between 1 and 128 in the Diagnostics parameter available in the MultiPoint
Parameters menu on the Master.
l A second computer or serial connection to run the diagnostics software.
l A user-supplied diagnostics cable (available from FreeWave).
l Tool Suite - Available from support.freewave.com.
l Registration is required to use this website.
Note: For more diagnostics information, Contact FreeWave Technical Support (on page 7).