5. Configure Point-to-MultiPoint Networks
LUM0020CD Rev June-2020 Page 65 of 112 Copyright © 2019FreeWave
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
Diagnostics
Setting Description
Description
The Diagnostics parameter determines how many slots out of 128 are dedicated
to diagnostics.
l Setting this parameter allows diagnostics data in the Network Diagnostics in
Tool Suite to be viewed at the Master radio in parallel with application data.
l Diagnostics is always secondary to actual transmitted data.
Example: If set to 10, 1 out of every 10 data slots is for diagnostics data.
If set to 100, 1 out of every 100 data slots is for diagnostics data.
Note: For more information, see Reading Diagnostics in Tool Suite on
page 72.
Diagnostics require:
l A setting of this parameter on the Master between 1 and 128.
l A second computer or serial connection to run the diagnostics software.
l A diagnostics cable. (Available from FreeWave)
l Diagnostics software.
FREEWAVE Recommends: When collecting diagnostics from an
LRS455A-C, LRS455A-CE, LRS455-T network, set the diagnostics
polling rate to 400 ms
or
higher.
Note: For more information about Diagnostics, Contact FreeWave
Technical Support (on page 7).
5.6.3. DTR Connect
Note: This parameter does not apply to the LRS455A-C, LRS455A-CE, LRS455-T radios.
5.6.4. Local Mode
Note: This parameter does not apply to the LRS455A-C, LRS455A-CE, LRS455-T radios.