Reference Manual

Table Of Contents
Appendix H:
Continuous Transmit Operating Instructions
In order to test a host OEM product with the LRS455A module installed, the host product will need to be tested for
complete product compliance. This sections describes how to enable the LRS455A for continuous transmit mode
in order to test the host product.
Hardware Setup:
Utilizing the same HW power up procedures defined in the Section 3, make sure the Serial communication is set
at:
a. Appropriate com port (COM1, for example)
b. 19200 baud
c. 8 bit
d. Parity: none
e. Stop: 1-bit
f. Flow Control: none
Pushing the reset button at any time will put the radio in idle mode (3 green LEDs) and will bring up the Main Menu
on the screen:
(0) Set Operation Mode
(1) Set Baud Rate
(2) Edit Call Book
(3) Edit Radio Transmission Characteristics
(4) Show Radio Statistics
(5) Edit MultiPoint Parameters
(6) TDMA Menu
(8) Chg Password
(Esc) Exit Setup
Enter Choice`
Radio Setup: (The DUT was shipped configured in Receive mode, on the mid channel, in 2-GSFK mode.)
LUM0020CD Rev June-2020 Page 108 of 112 Copyright © 2019FreeWave
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
LRS455A-C, LRS455A-CE, LRS455-T
User-Reference Manual